Blodgett B48-NFR, B48-RAD, B36-RAD, B36-NFR manual Installation of Sloped Enclosure If Ordered

Page 17

INFRARED/RADIANT COMPACT BROILER

INSTALLATION

CAUTION

ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS. USE ONLY SOAPY WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. ALL CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE APPLIANCE HAS BEEN PUT INTO OPERATION. TEST PRESSURE SHOULD NOT EXCEED 14" W.C.

1.Check that the control valves on the broiler are in the OFF position.

2.Purge the gas supply line to clean out dust, dirt, or other foreign matter before connecting the line to the broiler.

3.For wall-mount and countertop models, connect the gas supply to the inlet at right rear corner.

CAUTION

HOLD THE INLET SUPPLY PIPE WITH A WRENCH WHEN TIGHTENING ADDED FITTINGS TO AVOID DAMAGE TO THE REGULATOR, VALVE, AND OTHER COMPONENTS.

4.For the flue-riser-mounted model, either attach the gas supply to the gas pipe extending out of a hole on the rear of the flue riser; or (if the optional internal piping was ordered) connect the gas pipe extending from the rear of the broiler to the corresponding gas pipe extending from the rear of the range below the broiler, then attach the wall- shield (the rear of the flue riser).

5.Turn on the gas and check for leaks using soapy water.

STEP 4: INSTALL SLOPED ENCLOSURE (OPTIONAL ACCESSORY)

To install a sloped enclosure, remove the body-side screws and discard. Remove screws (3) on the bottom, toward the rear of the unit. Position the hanger clip and fasten with screws (3). Remove screws (3) in the bottom of the face plate. Slide the enclosure so that the bracket inserts into the hanger clip. Align the holes in the front of the enclosure with the holes in the bottom of the face plate. Fasten with screws (3).

Figure 7

Installation of Sloped Enclosure (If Ordered)

INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)

PAGE 17 OF 24

Image 17
Contents Infrared/Radiant Compact Broiler Burn Hazard Fire Hazard For Your SafetyExplosion and Asphyxiation Hazard Electric Shock HazardLocation of Serial Plate IntroductionClearances SpecificationsMinimum Clearances from Combustible Construction Dimensions GAS Supply VentilationINFRARED/RADIANT Compact Broiler Cleaning & Maintenance Explosion Hazard OperationOperation of Infrared Compact Broiler Broiler OperationLighting After GAS has Been Shut OFF Shutdown of Broiler Lighting Broiler PilotsDaily Cleaning and Maintenance Cleaning & MaintenanceMonthly Cleaning and Maintenance Semiannual Cleaning and MaintenanceSTAINLESS-STEEL Surfaces Unpacking InstallationImmediately Inspect for Shipping Damage Mount on Flue Riser of Range Mounting of Infrared/Radianr Compact Broiler on Flue-RiserMount on Wall Connect GAS Supply Attach Countertop LegsInstall Sloped Enclosure Optional Accessory Installation of Sloped Enclosure If OrderedCheck Broiler Operation Check the InstallationWIPE-CLEAN and SHUT-DOWN Appliance Troubleshooting ServiceAccess to Serviceable Parts Access to Serviceable PartsAdjustment of Broiler Pilots Adjustment of LOW SettingParts Adjustment of Broiler BurnersAdjustment of GAS Pressure Regulator Prop Gas Components INFRARED/RADIANT Compact Broiler Infrared Compact Broiler