ADJUSTMENT
Adjustment of Horizontal Zero
○1 Release the
○2 Turn the balance weight clockwise or counter clockwise until the tone arm is balanced horizontally.
N O T E
Be careful not to touch your finger to the stylus tip.
○3 Return the
Adjustment of Stylus Pressure
○1 Hold the balance weight with one hand as shown in the drawing, and rotate only counter ring to bring the numeral "0" of the ring into alignment with the center line on the
N O T E
In case the balance weight moved, do the adjustment of horizontal zero balance again.
○2 Turn the balance weight to present the reading on the gauge to the designed stylus force of your cartridge.As the counter ring moves in step with the balance weight, proper stylus pressure can be selected by reading the graduated ring directly.
N O T E
The appropriate stylus pressure (generally 3~
4g) needs to be set in order to generate the best performance. Please refer to the user's manual of the stylus.
Adjustment of Tone-arm Height
○1 The height of the
In case of 16mm cartridge height → Adjustment of
9mm(MAX).
N O T E
Generally, the highest setting of the
Illustration of Adjustment
Thebalanceweightandcartridgearebalanced,� |
|
� |
Excessive forward advancement of the balance � |
weight causes the cartridge side to be lowered. |
Excessive backward |
weight causes the cartridge side to be raised. |
Rotate � |
this part |
Rotate � |
this part |