ADJUSTMENT(S)
Adjustment of Horizontal Zero Balance
qCarefully release the tone arm from the tone arm clamp.
wTurn the balance weight clockwise or
NOTE
When adjusting the horizontal balance, take care not to touch the stylus.
eReturn the tone arm to resting position.
rAfter adjusting the horizontal balance, set the balance weight rotating only the counter ring to align with by the "0" weight setting to the center line of the arm axis.
NOTE
If the balance weight is moved, readjust the horizontal balance again.
tTurn the balance weight in the direction shown to adjust the stylus pressure (weight setting will depend on your stylus). When you turn the balance weight, the counter ring moves displaying, the weight setting
NOTE
If you put too much pressure on the stylus, it can cause the stylus to jump during scratch play and will shorten the stylus's life.
Tone arm height adjustment
A Tone arm height adjustment may be necessary for some cartridge types. The height can be adjusted up to 9mm by rotating the arm height adjustment screw.
Cartridge height 16mm
↓
Height adjustment not necessary
Cartridge height 25mm
↓
Height adjustment +9mm (Max)
NOTE
Be sure to tighten the arm height adjustment screw well. The stylus may jump/skip if the height setting is not secured.
The balance weight and cartridge are balanced, the
The balance weight setting is too heavy.
The balance weight setting is too light.
Balance Weight |
Rotate |
this part |
Counter Ring |
Balance Weight
Rotate this part
Counter Ring
Arm Height Adjustment Screw |
9