2.Using 8 of the included
3.Plug the 3 wire quick connect cord from the blower into the receptacle on the range hood canopy. Plug the 4 wire quick connect cord from the blower into the one end of the wiring harness then connect the other end of the wiring harness to the receptacle in the range hood canopy. These cords will only fit into the receptacles one way (Figure 2).
4.Plug the 3 wire quick connect cord from the blower into the receptacle on the range hood canopy. Plug the 4 wire quick connect cord from the blower into the one end of the wiring harness then connect the other end of the wiring harness to the receptacle in the range hood canopy. These cords will only fit into the receptacles one way (Figure 2).
5.Reinstall the rear bottom plate by fitting the back edge of the plate into the channel located on the back of the hood and reinstalling the two screws and washers removed in Step 1 (Figure 4).
| Receptacles | Screw | |
| Washer | ||
|
| ||
|
| Channel | |
Wire |
|
| |
Harness |
|
| |
Figure 2 | Blower | Bottom Plate | |
Figure 4 | |||
| |||
|
|
SECTION 3 | SECTION 4 |
Installation into 10" High Canopy |
1. Remove the rear bottom plate of the hood canopy. It is secured in place | Finishing the Installation |
with a screw and washer on either side (Figure 3). | 1. Install the included fuse into the electrical panel by turning the fuse cap |
Screw | counter clockwise and pulling out. Insert the included 1/4" x |
delay fuse in the holder and reinstall into the panel (Figure 5). | |
Washer |
|
| Cap |
Bottom Plate | Fuse |
| |
Figure 3 |
|
2. Lift blower up into the hood canopy and slide the keyhole slots in the blower | Figure 5 |
mounting flange over the two studs of the hood. Slide the blower into place |
|
and tighten the hex nuts on the mounting stud while lining up the 8 holes | NOTE: If you need to replace the fuse, replace with a 1/4" x | |
in the blower mounting flange to the 8 screw studs of the hood (Figure 1). | ||
3. Using 8 of the included | 2. | Refer to the hood instruction manual to complete the installation, for |
place and tighten all screws. Confirm that the blower is securely seated |
| maintenance, and before restoring power. |
in place and there are no air gaps around the blower gasket. | 3. | The blower is covered under the range hood’s warranty. |
|
REPLACEMENT PARTS DIAGRAM
# | Qty. | Description | Replacement Part # |
| 3 |
|
| ||||
1 | 1 | Blower Assembly | 5S1136110 |
|
|
2 | 1 | Blower Gasket | 5S1136112 |
|
|
3 | 8 | Grommet | 5S1136101 |
| 4 |
4 | 8 | Washer | 5S1136102 |
|
|
5 | 8 | 5S1136103 | 9 | 2 | |
6 | 1 | Capacitor | 5S1136116 | ||
7 | 1 | Screw | 5S1136117 |
|
|
8 | 1 | Wire Harness | 5S1136118 |
| 6 |
9 | 1 | Fuse | 5S1136106 |
| |
|
|
5
7
8
1
111597002 New | www.airkinglimited.com | 2 of 8 |