Zephyr AK8200AS Troubleshooting Procedures for Tornado II and Tornado, Issue Cause What to do

Page 20

Troubleshooting

www.zephyronline.com

TROUBLESHOOTING PROCEDURES FOR TORNADO II AND TORNADO III

Issue

Cause

What to do

After installation,

1.

The power source is not turned ON.

1.

Make sure the circuit breaker and the unit’s

the unit doesn’t

 

 

 

power is ON.

work.

 

 

 

 

2.

The power line and the cable locking connector

2.

Check the power connection with the unit is

 

 

 

is not connecting properly.

 

connected properly.

 

 

 

 

 

 

3.

The switch board and control board wirings are

3.

Make sure the wirings between the switch

 

 

disconnected.

 

board and control board are connected

 

 

 

 

properly.

 

4.

The wires on control board are loose.

4.

Make sure the wires on the control board are

 

 

 

 

connected properly.

 

5.

The switch board or control board is defective.

5.

Change the switch board or control board.

Light works,

1.

The motor is defective, possible seized.

1.

Change the motor.

but motor is not

 

 

 

 

2.

The thermally protected system detects if the

2.

The motor will function properly after the

turning.

 

motor is too hot to operate and shuts the motor

 

thermally protected system cool down.

 

 

 

 

 

down.

 

 

 

 

 

 

 

 

3.

Damaged capacitor.

3.

Change the capacitor.

 

4.

The motor wire is not connected.

4.

Make sure the motor wire is plugged into the

 

 

 

 

molex connector.

The unit is

1.

The motor is not secure in place.

1.

Tighten the motor in place.

vibrating.

 

 

 

 

2.

Damaged blower wheel.

2.

Change the blower.

 

 

 

 

 

 

 

3.

The hood is not secured in place.

3.

Check the installation of the hood.

The motor is

1.

Defective halogen bulb.

1.

Change the halogen bulb.

working, but the

 

 

 

 

2.

The light bulb is loose.

2.

Tighten the light bulb.

lights are not.

3.

The wires on the control board are loose.

3.

Make sure the wires on control board are

 

 

 

 

 

connected properly.

 

 

 

 

 

The hood is

1.

The hood might be hanging too high from the

1.

Adjust the distance between the cook top and

not venting out

 

cook top.

 

the bottom of the hood within 26” and 36”

properly.

 

 

 

range.

 

2.

The wind from the opened windows or opened

2.

Close all the windows and doors to eliminate

 

 

doors in the surrounding area are affecting the

 

the outside wind fl ow.

 

 

ventilation of the hood.

 

 

 

3.

Blockage in the duct opening or duct work.

3.

Remove all the blocking from the duct work or

 

 

 

 

duct opening.

 

4.

The direction of duct opening is against the wind.

4. Adjust the duct opening direction.

 

5.

Using the wrong size of ducting.

5.

Change the ducting to correct size.

 

 

 

 

 

Filter is vibrating.

1.

Filter is loose.

1.

Adjust or change the fi lter.

 

 

 

 

 

 

2.

Spring clip is broken inside filter opening

2.

Change the spring clip.

 

 

 

 

 

RF Remote

1.

Battery is dead

1.

Replace battery with type A23 12v

control does not

 

 

 

 

2.

Poor communication with the power pack

2.

Remote control must be within 15 ft of power

work

 

 

 

pack

 

 

 

 

 

 

 

 

 

 

3.

RF remote lost communication with power pack

3.

Reset power pack and remote by switching

 

 

 

 

power off at the circuit breaker for 5 minutes.

 

 

 

 

Pace remote on counter top near power pack

 

 

 

 

and switch the circuit breaker back on.

18

Image 20
Contents Use, Care, and Installation Guide Page Table of Contents InstallationFeatures & Controls MaintenanceImportant Safety Notice To Reduce the Risk of Range TOP Grease FireFederal Communication Commission Interface Statement OperationElectrical Requirements Materials ListInstallation Ducting Calculation Sheet Duct pieces Equivalent number Total Length x usedInstallation Mounting Height & Clearance DuctingAK8200AS Vertical Ducting Horizontal DuctingSome Ducting Options InstallationDucting Options Specifications Cable Lock Installation ElectricalElectrical Before installing into cabinet. b Power PackRemove support screw from top of Power Pack Installation Single and Dual Internal Blowers For Remote Blower Preparation Instructions Turn toInstallation Remote Blower PreparationFeatures & Controls Touch Controls Blower On/OffFeatures & Controls Touch ControlsRF Remote Control Remote Control FeaturesRemote Control Maintenance Follow instructions below for replacing batterySurface Maintenance Installing FiltersMaintenance Cleaning Maintenance Lights Replacing Light BulbsIssue Cause What to do TroubleshootingTroubleshooting Procedures for Tornado II and Tornado List of Parts and Accessories Replacement PartsOptional Accessories DescriptionLimited Warranty

AK8300ASX, AK8200AS specifications

The Zephyr AK8200AS and AK8300ASX are two cutting-edge air conditioning systems that represent the pinnacle of modern HVAC technology. Designed for both residential and commercial applications, these models combine efficiency, performance, and user-friendly features to provide optimal indoor comfort.

One of the standout characteristics of the AK8200AS and AK8300ASX is their energy efficiency. Both models utilize advanced inverter technology, which allows the units to adjust their cooling capacity based on the real-time cooling demands of the space. This not only ensures consistent temperature control but also significantly reduces energy consumption, making them environmentally friendly and cost-effective.

In terms of cooling capacity, the AK8200AS boasts a robust output that makes it suitable for medium-sized rooms, while the AK8300ASX is designed for larger spaces, providing an even higher capacity. This flexibility allows users to select the model that best meets their specific needs.

Another key feature of these air conditioning systems is the whisper-quiet operation. Thanks to their sophisticated design and engineering, both units operate at a sound level that is unobtrusive, allowing for a peaceful environment ideal for resting, working, or entertaining.

The filtration systems in the AK8200AS and AK8300ASX are also noteworthy. They incorporate multi-layer filters that not only capture dust and allergens but also help to neutralize odors, ensuring that the air quality remains clean and fresh. This feature is particularly beneficial for individuals with respiratory issues or allergies.

User convenience is enhanced with the inclusion of smart technology integration. Both models are compatible with various smart home systems, allowing users to control their air conditioning remotely via smartphones or voice-activated devices. This added functionality provides the freedom to adjust settings, monitor energy usage, and receive maintenance reminders seamlessly.

In terms of design, the AK8200AS and AK8300ASX feature a sleek and modern aesthetic that complements a variety of interiors. Their compact size also allows for easy installation in various settings, including wall-mounted and ceiling-mounted options.

In conclusion, the Zephyr AK8200AS and AK8300ASX offer an impressive combination of energy efficiency, powerful cooling capacity, quiet operation, superior air filtration, and modern smart technology. These features not only enhance comfort but also contribute to a healthier indoor environment, making them a leading choice for consumers seeking reliable air conditioning solutions.