Zephyr AK8300ASX, AK8200AS manual Installation Ducting Calculation Sheet

Page 7

Duct pieces

Equivalent number

 

Total

 

length x used

=

 

3-1/ 4” x 10”

1 Ft.

x (

)

=

Ft.

Rect.,

 

 

 

 

 

straight

 

 

 

 

 

6” Round,

1 Ft.

x (

)

=

Ft.

straight

 

 

 

 

 

7”-10” Round,

1 Ft.

x (

)

=

Ft.

straight

 

 

 

 

 

3-1/ 4” x 10”

15 Ft.

x (

)

=

Ft.

Rect.900

 

 

 

 

 

elbow

 

 

 

 

 

3-1/ 4” x 10”

9 Ft.

x (

)

=

Ft.

Rect.450

 

 

 

 

 

elbow

 

 

 

 

 

3-1/ 4” x 10”

24 Ft.

x (

)

=

Ft.

Rect.900

 

 

 

 

 

flat elbow

 

 

 

 

 

3-1/ 4” x 10”

30 Ft.

x (

)

=

Ft.

Rect.

 

 

 

 

 

wall cap

 

 

 

 

 

with damper

 

 

 

 

 

3-1/ 4” x 10”

5 Ft.

x (

)

=

Ft.

Rect.to

 

 

 

 

 

6” round

 

 

 

 

 

transition

 

 

 

 

 

3-1/ 4” x 10”

20 Ft.

x (

)

=

Ft.

Rect.to

 

 

 

 

 

6” round

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

6” Round,

15 Ft.

x (

)

=

Ft.

900 elbow

 

 

 

 

 

6” Round,

9 Ft.

x (

)

=

Ft.

450 elbow

 

 

 

 

 

 

Subtotal column 1 =

Ft.

Duct pieces

Equivalent number

Total

 

length x used

 

=

6” Round

30 Ft.

x (

)

=

Ft.

wall cap

 

 

 

 

 

with damper

 

 

 

 

 

6” Round,

30 Ft.

x (

)

=

Ft.

roof cap

 

 

 

 

 

6” round to

1 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

6” round to

16 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

7” - 10”

15 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

900 elbow

 

 

 

 

 

7” - 10”

9 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

450 elbow

 

 

 

 

 

7” - 10”

30 Ft.

x (

)

=

Ft.

Round

 

 

 

 

 

wall cap

 

 

 

 

 

with damper

 

 

 

 

 

7” - 10”

30 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

roof cap

 

 

 

 

 

7” round to

8 Ft.

x (

)

=

Ft.

3 1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

7” round to

23 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

 

Subtotal column 2 =

Ft.

 

Subtotal column 1 =

Ft.

 

Total ductwork

 

=

Ft.

Installation – Ducting Calculation Sheet

Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet.

5

Image 7
Contents Use, Care, and Installation Guide Page Maintenance Table of ContentsInstallation Features & Controls To Reduce the Risk of Range TOP Grease Fire Important Safety NoticeElectrical Requirements OperationFederal Communication Commission Interface Statement List MaterialsDuct pieces Equivalent number Total Length x used Installation Ducting Calculation SheetHorizontal Ducting Installation Mounting Height & ClearanceDucting AK8200AS Vertical DuctingDucting Options InstallationSome Ducting Options Specifications Electrical Installation ElectricalCable Lock Remove support screw from top of Power Pack Power PackBefore installing into cabinet. b For Remote Blower Preparation Instructions Turn to Installation Single and Dual Internal BlowersRemote Blower Preparation InstallationBlower On/Off Features & Controls Touch ControlsTouch Controls Features & ControlsFollow instructions below for replacing battery RF Remote ControlRemote Control Features Remote Control MaintenanceMaintenance Cleaning Installing FiltersSurface Maintenance Replacing Light Bulbs Maintenance LightsTroubleshooting Procedures for Tornado II and Tornado TroubleshootingIssue Cause What to do Description List of Parts and AccessoriesReplacement Parts Optional AccessoriesLimited Warranty