Zephyr AK8200AS, AK8300ASX Important Safety Notice, To Reduce the Risk of Range TOP Grease Fire

Page 4

Important Safety Notice

READ AND SAVE THESE INSTRUCTIONS

www.zephyronline.com

WARNING

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.

WARNING

TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a.Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.

b.Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning agents or detergents. Suitable for use in household cooking area.

WARNING

TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:

a.Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b.Always turn hood ON when cooking at high heat or when fl aming food

c.Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

d.Use proper pan size. Always use cookware appropriate for the size of the surface element.

e.Keep fan, fi lters and grease laden surfaces clean.

f.Use high setting on hood only when necessary.

g.Don’t leave hood unattended when cooking.

h.Always use cookware and utensils appropriate for the type of and amount of food being prepared.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:

a.SMOTHER FLAMES with a close-fi tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the fl ames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

b.NEVER PICK UP A FLAMING PAN – You may be burned.

c.DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.

d.Use an extinguisher ONLY if:

1.You know you have a Class ABC extinguisher, and you already know how to operate it.

2.The fi re is small and contained in the area where it started.

3.The fi re department is being called.

4.You can fi ght the fi re with your back to an exit

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a.Installation work and electrical wiring must be done by qualifi ed person(s) in accordance with all applicable codes and standards. Including fi re-rated construction.

b.Suffi cient air is needed for power combustion and exhausting of gases through the fl ue (chimney) of fuel burning equipment to prevent back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

c.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

d.Ducted fans must always vent to the outdoors.

e.NEVER place a switch where it can be reached from a tub or shower.

f.Make sure the power is off before installing, wiring or maintenancing.

2

Image 4
Contents Use, Care, and Installation Guide Page Table of Contents InstallationFeatures & Controls MaintenanceImportant Safety Notice To Reduce the Risk of Range TOP Grease FireElectrical Requirements OperationFederal Communication Commission Interface Statement Materials ListInstallation Ducting Calculation Sheet Duct pieces Equivalent number Total Length x usedInstallation Mounting Height & Clearance DuctingAK8200AS Vertical Ducting Horizontal DuctingDucting Options InstallationSome Ducting Options Specifications Electrical Installation ElectricalCable Lock Remove support screw from top of Power Pack Power PackBefore installing into cabinet. b Installation Single and Dual Internal Blowers For Remote Blower Preparation Instructions Turn toInstallation Remote Blower PreparationFeatures & Controls Touch Controls Blower On/OffFeatures & Controls Touch ControlsRF Remote Control Remote Control FeaturesRemote Control Maintenance Follow instructions below for replacing batteryMaintenance Cleaning Installing FiltersSurface Maintenance Maintenance Lights Replacing Light BulbsTroubleshooting Procedures for Tornado II and Tornado TroubleshootingIssue Cause What to do List of Parts and Accessories Replacement PartsOptional Accessories DescriptionLimited Warranty

AK8300ASX, AK8200AS specifications

The Zephyr AK8200AS and AK8300ASX are two cutting-edge air conditioning systems that represent the pinnacle of modern HVAC technology. Designed for both residential and commercial applications, these models combine efficiency, performance, and user-friendly features to provide optimal indoor comfort.

One of the standout characteristics of the AK8200AS and AK8300ASX is their energy efficiency. Both models utilize advanced inverter technology, which allows the units to adjust their cooling capacity based on the real-time cooling demands of the space. This not only ensures consistent temperature control but also significantly reduces energy consumption, making them environmentally friendly and cost-effective.

In terms of cooling capacity, the AK8200AS boasts a robust output that makes it suitable for medium-sized rooms, while the AK8300ASX is designed for larger spaces, providing an even higher capacity. This flexibility allows users to select the model that best meets their specific needs.

Another key feature of these air conditioning systems is the whisper-quiet operation. Thanks to their sophisticated design and engineering, both units operate at a sound level that is unobtrusive, allowing for a peaceful environment ideal for resting, working, or entertaining.

The filtration systems in the AK8200AS and AK8300ASX are also noteworthy. They incorporate multi-layer filters that not only capture dust and allergens but also help to neutralize odors, ensuring that the air quality remains clean and fresh. This feature is particularly beneficial for individuals with respiratory issues or allergies.

User convenience is enhanced with the inclusion of smart technology integration. Both models are compatible with various smart home systems, allowing users to control their air conditioning remotely via smartphones or voice-activated devices. This added functionality provides the freedom to adjust settings, monitor energy usage, and receive maintenance reminders seamlessly.

In terms of design, the AK8200AS and AK8300ASX feature a sleek and modern aesthetic that complements a variety of interiors. Their compact size also allows for easy installation in various settings, including wall-mounted and ceiling-mounted options.

In conclusion, the Zephyr AK8200AS and AK8300ASX offer an impressive combination of energy efficiency, powerful cooling capacity, quiet operation, superior air filtration, and modern smart technology. These features not only enhance comfort but also contribute to a healthier indoor environment, making them a leading choice for consumers seeking reliable air conditioning solutions.