W O L F S E A L E D B U R N E R R A N G E T O P S
P L A N N I N G I N F O R M A T I O N
Wolf sealed burner rangetops come in 30" (762), 36" (914) and 48" (1219) widths. Specifications on the following pages provide overall dimen- sions, finished rough opening dimensions and installation specifics for each size of sealed burner rangetop. We have minimized the infor- mation contained in the illustrations, concentrat- ing on the critical information you need to plan your installation.
IMPORTANT NOTE: Caution must be used in planning the proper installation of the Wolf sealed burner rangetop to avoid fires or damage to adjacent cabinetry or kitchen equipment. Please follow the minimum clearances estab- lished in the finished rough opening dimensions. Refer to specifications on the following pages for your model.
It is recommended that you use a Wolf Pro ventilation hood or hood liner with the Wolf sealed burner rangetop. Refer to pages
B U R N E R R A T I N G
Sealed Burner Rangetops
Surface Burners 15,000 Btu/hr (4.4 kW) with 950 Btu/hr (.3 kW) delivered at simmer
(1)9,200 Btu/hr (2.7 kW) with 325 Btu/hr (.1 kW) delivered at simmer
Infrared Charbroiler 16,000 Btu/hr (4.7 kW)
Infrared Griddle |
|
Natural Gas | 15,000 Btu/hr (4.4 kW) |
LP Gas | 13,000 Btu/hr (3.8 kW) |
Infrared Double Griddle | |
Natural Gas | (2) 15,000 Btu/hr (4.4 kW) |
LP Gas | (2) 13,000 Btu/hr (3.8 kW) |
French Top | 15,000 Btu/hr (4.4 kW) |
Refer to the specific model requirements for risers in
E L E C T R I C A L G A S R E Q U I R E M E N T S
Specifications on the following pages provide electrical and gas requirements for each size of sealed burner rangetop.
The Wolf sealed burner rangetop requires a 110/120 V AC, 50/60 Hz electrical supply to operate the electronic ignition system. The power supply cord is equipped with a
IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
Wolf sealed burner rangetops are designed to operate on natural gas at 5" (12.5 mb) WC (water column) pressure or LP (propane) gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC for LP gas. The maximum gas supply pressure to the regulator should never exceed 14" (34.9 mb) WC, .5 psi (3.5 kPa).
If local codes permit, a certified, 3' (.9 m) long,
1/2" or 3/4" I.D. flexible metal appliance connector is recommended for connecting the rangetop to the gas supply line.
IMPORTANT NOTE: A separate external gas
The platform for the rangetop must be 3/4" (19) thick and include a
Locate electrical and gas supply within the shaded area shown in the Installation Specifications illustration for your model.
You must follow all National Electrical Code and gas regulations. In addition, be aware of local codes and ordinances when installing your services.
H I G H A L T I T U D E
Wolf sealed burner rangetops using natural gas function up to an altitude of 8,000' (2438 m) without any adjust- ment. Natural gas and LP gas installa- tions from 8,000' (2438 m) to 11,000'
(3353 m) need the high altitude kit. Contact your Wolf dealer for details.
73