Wolf Appliance Company PL342212 dimensions Installation N O T E S

Page 5

Planning Information

Pro Ventilation Hood Liner

M O D E L P L 3 4 2 2 1 2

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications for overall dimensions and installation specifics.

Wolf Pro ventilation hood liners are recom- mended for use with any Wolf cooking appli- ance, and should be as least as wide as the cooking surface. It is recommended that the hood overlap the cooking surface by 3" (76) on either side.

Installation of all Pro hood liners should be 30" (762) to 36" (914) from the bottom of the decorative hood to the countertop. Follow the dimensions shown in the Installation illustration on page 4.

Wolf Pro hood liners are shipped without a blower assembly. Internal, in-line or remote blower assemblies are available. Blower options also vary with the volume of air that needs to be moved and the length of the duct run. Refer to the charts at the end of this section for Pro ventilation recommendations and blower options.

IMPORTANT NOTE: Install this ventilation hood liner only with a Wolf blower.

Pro hood liners require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker.

Placement of the electrical supply is not critical, as long as you provide enough 120 V AC, 60 Hz power cable to make the electrical connection.

Locate electrical within the shaded area shown in the Installation illustration on page 4.

You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.

A decorative hood can be created out of wood, plaster, tile or metal. The shape of the decorative hood is not critical. The only place where the liner and outside cover must meet is at the bottom edge of the metal liner. The deco- rative hood and liner must fit at the bottom edge in both width and depth.

The height of the liner does not have to be the same as the height of the decorative hood and is generally shorter.

The top depth of the liner, which is 12" (305) standard, must be less than the interior depth of the decorative hood. Measure the interior depth of the hood at the top height of the liner to make sure the liner will fit inside the decora- tive hood.

The hood liner comes standard with a 4"

(102)lower reveal. Be sure to include this dimension in your decorative hood selection.

Always use the interior measurements of the decorative hood and measure in multiple places. Use the smallest dimensions to verify hood liner specifications.

Refer to the installation instructions shipped with each Wolf product for detailed specifica- tions. This information can also be found on our website, wolfappliance.com.

Dimensions in parentheses are in

millimeters unless otherwise specified.

5

Image 5
Contents Pro Ventilation Hood Liner E R a L L D I M E N S I O N S A T U R E SC E S S O R I E S Specification SO W E R O P T I O N S M E N S I O N S Installation Specification SInstallation N O T E S C T I N G C O N S I D E R a T I O N S L F B L O W E R a S S E M B L I E S O V E N T I L a T I O N B L O W E R O P T I O N S O V E N T I L a T I O N C F M R E C O M M E N D a T I O N S