AEG DK 1190, DK 1160 installation instructions Wall unit mounting Fig

Page 16

Wall unit mounting - Fig. 7

Put the template onto the wall (1) and drill two Ø12mm holes (2).

Fit two hooks (3) on the drilled holes.

Hang the hood on the hooks and adjust the position of the hood using the two screws on the bottom of the hooks (5).

Remove the metal filters (4) and mark two points (6). Remove the hood and drill two Ø8mm holes on the marked points.

Fit two Ø8mm wall dowels (7), Hang again the hood and fix the hood definitively with two screws 5X45 (8).

Fix the chimney support (10) with two screws 5 x 45 mm (9) and two wall dowels (11) on the wall close to the ceiling.

For exhausting version: Fit the connection ring (S) on the top of the hood with two screws Ø 3,5 x 6,5 mm (12S) then fit an axhausting pipe long enough to reach the outside (13S).

For recycling version: Fix definitively the deflector (13K) on the top of the hood with two screws Ø 3,5 x 6,5 mm (12K).

Prepare the electric connection (14) (see relative chapter).

Fit the chimney (15) and fix it on the chimney support with two screws 3,0 x 9 mm (16).

The lower part of the chimney must be slided down and inserted on the housing on the upper part of the hood (17).

Fit the two grids (18) on both sides of the chimney.

78

Image 16
Contents Page Contents For kitchen unit installer Safety warningsFor user Page Introduction Extractor versionFilter Version Hood Operation Metal grease filter Maintenance and careOpen the metal grease filter Carbon filter Changing the light bulb Special accessories CleaningTechnical assistance service Guarantee conditions European GuaranteePage Mounting accessories included Technic DetailsSafety warnings for the electrician Electrical connectionWall unit mounting Fig 120 mm LI1USB Ed.03/02