Ariston CX65SM2XAUS, CX65SM2AUS specifications Electrical connection, Mounting a Power Supply Cable

Page 3

 

 

 

 

 

 

• If the cooker is

 

 

 

 

 

 

installed underneath a

 

 

HOOD

 

 

 

 

 

 

 

 

 

wall cabinet, there must

 

 

Min. 600mm.

 

 

min. 700 mm. without hood

Min. 420mm.

 

Min. 420mm.

min. 650 mm. with hood

be a minimum distance

 

 

 

 

of 420 mm between

 

 

this cabinet and the top

 

 

of the hob.

 

 

 

 

 

 

 

 

 

This distance should

 

 

 

 

 

 

be increased to 700

 

 

 

 

 

 

mm if the wall cabinets

are flammable (see figure).

Do not position blinds behind the cooker or less than 200 mm away from its sides.

Any hoods must be installed according to the instructions listed in the relevant operating

manual.

GB

N L

To install the cable, proceed as follows:

_Remove the wire clamp screw and the three contact screws L-N-

Fasten the wires beneath the heads of the screws using the following color scheme : Blue (N) Brown (L) Yellow-Green

Fasten the supply cable in place with the clamp and close the cover of the terminal board.

Levelling

The cooker is fitted with a safety chain that must be attached to a hook, secured to the wall behind the appliance.

Electrical connection

Ovens with a three-pole power supply cable are designed to operate with alternated current at the supply frequency and voltage indicated on the data plate (at the bottom of the oven dashboard). The earthing conductor of the cable is the yellow-green conductor.

Connecting the power supply cable to the mains. Fit a normalized plug to the cable, which corresponds to the load indicated on the data plate;

If it is necessary to level the appliance, screw the adjustable feet into the places provided on each corner of the base of the cooker (see figure).

The legs* fit into the slots on the underside of the base of the cooker.

Mounting a Power Supply Cable

Opening the terminal board:

_Using a screwdriver, prise on the side tabs of the terminal board cover;

_Pull open the cover of the terminal board.

if the cooker is connected directly to the mains, an omnipolar circuit-breaker with a minimum opening of 3 mm between the contacts, suitable for the load indicated and complying with current directives, must be installed between the appliance and the mains (the earthing wire must not be interrupted by the circuit-breaker). The power supply cable must be positioned so that it does not exceed room temperature by 50°C at any point of its length. Before making the connection check that:

the limiter valve and the home system can support appliance load (see data plate);

the power supply system has an efficient earthing connection which complies with the provisions of current regulations and the law;

there is easy access to the socket or the omnipolar circuit-breaker once the cooker has

been installed.

￿Do not use reducers, adapters or shunts as these could cause heating or burning.

3

Image 3
Contents Cooker and Oven Operating InstructionsPositioning and levelling InstallationElectrical connection Mounting a Power Supply CableBlue Neutral N Brown Live L Green and Yellow Earth E Gas connectionAdapting to different types of gas CX65SM2 AUS CX65SM2 X AUS Table of burner and nozzle specificationsDescription Appliance Overall viewControl panel Using the hob Using the ovenStart-up and use Cooking modes Using the cooking timerOven Oven cooking advice tableRespecting and conserving the environment Precautions and tipsGeneral safety DisposalCare and maintenance