Ariston CX65SM2AUS Gas connection, Blue Neutral N Brown Live L Green and Yellow Earth E

Page 4

How to connect an alternative plug

Gas connection using a flexible rubber hose

GB

GREEN &

YELLOW

BROWN

13 amp fuse

 

BLUE

CROSS-BAR

 

CORD GRIP

The wires in this mains lead are coloured in accordance with the following code:

BLUE “NEUTRAL” (N) BROWN “LIVE” (L)

GREEN AND YELLOW “EARTH” (E)

Make the connection using a gas hose that complies with requirements set forth by the current National Regulations. The appliance is factory set for connection to a natural gas supply. A fitting "R" with

 

 

 

a conical thread ISO7-1

 

 

 

(1/2 gas) and a seal "G"

 

 

 

is fitted at the end "L"

 

 

L

of the pipe to be

 

 

 

connected to the gas

 

 

G

mains. This fitting

 

 

should not be removed.

 

 

 

 

 

 

When the connection

￿Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible.

￿The cable must not be bent or compressed.

￿The cable must be checked regularly and replaced by authorised technicians only.

￿The manufacturer declines any liability should

these safety measures not be observed.

Gas connection

Connection to the gas network or to the gas cylinder may be carried out using a flexible rubber or steel hose, in accordance with current national legislation and after making sure that the appliance is suited to the type of gas with which it will be supplied (see the rating sticker on the cover: if this is not the case see below). When using liquid gas from a cylinder, install a pressure regulator which complies with current national regulations. To make connection easier, the gas supply may be turned sideways*: reverse the position of the hose holder with that of the cap and replace the gasket that is supplied with the appliance.

￿Check that the pressure of the gas supply is consistent with the values indicated in the Table of burner and nozzle specifications (see below). This will ensure the safe operation and durability of your appliance while maintaining efficient energy consumption.

 

 

R

pipe (flexible or rigid) is

 

 

 

 

 

dismounted, the fitting

 

 

 

"R" should be locked in

 

 

 

 

 

 

place using a spanner

before unscrewing the metal pipe bolt. This is to prevent the fitting "R" from slipping and so as not to cause any leaks from sleeve "L". If the appliance is designed for left and right gas connection, the cap should be inverted and the seal supplied with the appliance should be replaced when changing the connection.

Once the connection has been performed, make sure that the hose:

Does not come into contact with any parts that reach temperatures of over 50°C.

Is not subject to any pulling or twisting forces and that it is not kinked or bent.

Does not come into contact with blades, sharp corners or moving parts and that it is not compressed.

Is easy to inspect along its whole length so that its condition may be checked.

Is shorter than 1500 mm.

Fits firmly into place at both ends, where it will be fixed using clamps that comply with current regulations.

￿If one or more of these conditions is not fulfilled or if the cooker must be installed according to the conditions listed for class 2 - subclass 1 appliances (installed between two cupboards), the flexible steel hose must be used instead (see below).

4

Image 4
Contents Operating Instructions Cooker and OvenInstallation Positioning and levellingMounting a Power Supply Cable Electrical connectionGas connection Blue Neutral N Brown Live L Green and Yellow Earth EAdapting to different types of gas Table of burner and nozzle specifications CX65SM2 AUS CX65SM2 X AUSOverall view Description ApplianceControl panel Using the oven Using the hobStart-up and use Using the cooking timer Cooking modesOven cooking advice table OvenPrecautions and tips General safetyDisposal Respecting and conserving the environmentCare and maintenance