TABLE of CONTENTS

Pg 2-4

INTRODUCTION

Pg 14

GAS INSTALLATION

 

Warranty

15-16 FINISHING

 

General Instructions

 

 

Logo Placement

 

General Information

 

 

 

Front Cast Installation

 

Care of Glass & Plated Parts

 

 

 

Glass Door Closing & Opening

 

Shipping Bracket

 

 

 

Log Placement

5

LOCATION & CLEARANCES

 

17-18 OPERATION / MAINTENANCE

 

 

6-12 DIRECT VENT SPECIFICS MODEL GDS60

Vent Lengths/Air Terminal Locations

Special Installation Example

Offset Installation Example

Horizontal Terminations

Orifice Replacement

Top Vent to Rear Vent Modification

Venting Parameters

Wall & Ceiling Protection

Horizontal Venting Installation

Vertical Venting Installation

Stove Vent Connection

Mobile Home Installation

13-14 B-VENT SPECIFICS

MODEL GS60

Chimney Installation

'B' Vent Installation

Combustion Air

Adding Vent Sections

Flashing and Storm Collar Installation

Spill Switch

Venting Action Check

Operating Instructions

Maintenance

19 BLOWER INSTALLATION

19 ADJUSTMENTS

Pilot Burner Adjustment

Venturi Adjustments

Restricting Vertical Vents

20-21 REPLACEMENTS

Ordering Replacement Parts

Termination Kits

Replacement Parts

Accessories

22-23 TROUBLE SHOOTING GUIDE

24 SERVICE HISTORY

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

WARNING

The stove is a vented gas-fired heater. Do not burn wood or other materials in this stove.

Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the stove.

Due to high temperatures, the stove should be located out of traffic and away from furniture and draperies.

Clothing or other flammable material should not be placed on or near the stove.

Any safety screen or guard removed for servicing must be replaced prior to operating the stove.

It is imperative that the control compartments, burners and circulating blower and its passageway in the stove and venting system are kept clean. The stove and its venting system should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The stove area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.

Under no circumstances should this stove be modified.

This stove must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.

Do not use this stove if any part has been under water. Immediately call a qualified service technician to inspect the stove and to replace any part of the control system and any gas control which has been under water.

Do not operate the stove with the glass door opened, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Do not strike or slam shut the stove glass door.

This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.

NOTE: changes, other than editorial, are denoted by a vertical line in the margin.

W415-0158 / E / 02.19.04

Image 2
Contents For Your Safety Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Care of GLASS, and Plated Parts General InstructionsGeneral Information Shipping BracketB C Location & ClearancesGDS60 and GS60 Direct Vent Specifics Model GDS60 Venting Lengths AIR Terminal LocationsAIR Terminal Installations 40 ft. maximum vertical run length 7 ft. horizontal run B Special Installation Example Offset Installation Example40 ft. maximum vertical run length Changing a TOP Vent to a Rear Vent Orifice ReplacementRear Vent Horizontal Termination Wall & Ceiling Protection Horizontal InstallationVenting Parameters Vertical Installation Horizontal Venting Installation Do not Fill this Space with ANY Type of MaterialStove Vent Connection Vertical Venting InstallationMobile Home Installation Vent Specifics Model GS60 Chimney InstallationInstalling B Vent Vent Model GS60 onlySolution. do not USE Open Flame Adding Vent Sections GAS InstallationInstalling Flashing Storm CollarGlass Door Installation Removal Logo PlacementRetainer Front Cast Installation FinishingLOG Placement Operation / Maintenance Operating InstructionsTo Turn OFF GAS MaintenanceLighting Instructions Pilot Burner Adjustment Blower InstallationAdjustments Venturi AdjustmentReplacements Ing informationW415-0158 / E Trouble Shooting Guide Symptom Problem Test SolutionModel GDS60 only Model GDS60 only Main burner flame isFireplace Service History

GDS60-N, GS60-N, GDS60-P, GS60-P specifications

Napoleon Fireplaces offers an impressive line of gas fireplaces, including the GDS60-N, GS60-N, GS60-P, and GDS60-P models, which represent the pinnacle of style, efficiency, and technology in modern heating solutions. These fireplaces are designed to enhance the comfort of your living space while ensuring an inviting atmosphere.

One of the standout features of the GDS60-N and GS60-N models is the unique Design and Style Series, which provides flexibility in customization. Homeowners can choose from a variety of finishes, including classic and contemporary styles, to seamlessly integrate the fireplace into their existing décor. The clean lines and elegant design make these units a focal point in any room.

Both models prioritize efficiency, boasting impressive heating capabilities that can warm spaces of significant size. They utilize advanced combustion technology, ensuring that heat is distributed evenly while maximizing fuel efficiency. The GDS60-P and GS60-P models offer similar features but come with a premium touch, providing enhanced aesthetics with their panoramic viewing area that showcases a mesmerizing flame display.

The burner system in these fireplaces is engineered for consistent performance, allowing users to enjoy the beauty of flickering flames with minimal maintenance. Innovative features such as the exclusive PHAZER log set provide a realistic fire effect, further enhancing the ambiance and visual appeal of the fireplace.

Additionally, Napoleon fireplaces incorporate top-tier safety measures, including an automatic shut-off feature, which ensures peace of mind for users. The intuitive remote control system enables easy temperature adjustments and flame settings, allowing for personalized comfort at the touch of a button.

Another notable characteristic is the easy installation process. These units are designed for both direct venting and conventional venting, offering versatility that caters to various home layouts. The manufacturers have placed a strong emphasis on craftsmanship, ensuring that each unit not only performs optimally but also lasts for years to come.

In conclusion, the Napoleon Fireplaces GDS60-N, GS60-N, GS60-P, and GDS60-P models epitomize the perfect fusion of technology, efficiency, and design. Homeowners looking for a reliable heating solution that doesn't compromise on style will find these gas fireplaces to be an excellent choice. With their captivating aesthetics, advanced features, and superior safety specifications, Napoleon continues to set a high standard in the fireplace industry.