OPERATION / MAINTENANCE

PURGE ALL GAS LINES WITH THE GLASS DOOR OPEN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT THE BURNER BEFORE CLOSING THE DOOR.

ALLOW SEVERAL MINUTES (5-15) FOR THE FLAME TO STABILIZE AFTER IGNITION.

MODEL GS60 ONLY: SPILL SWITCH

This is a thermally activated switch, attached to the back of the chimney adapter, which senses the change in temperature and shuts down the gas valve in the event of a blocked or disconnected vent. It acts as a safety

shut-off to prevent a build up of carbon monoxide or an

explosion of unburnt gases during start up. If the flue is blocked or has no "draw", the spill switch will auto-

matically shut off the supply of gas within about 5-10

minutes.

TAMPERING WITH THE SWITCH CAN RESULT IN CARBON MONOXIDE (CO) POISONING AND POSSI- BLE DEATH.

MODEL GS60 ONLY:VENTING ACTION CHECK

A CHECK FOR CORRECT VENTING ACTION MUST BE MADE BEFORE THE INSTALLED STOVE IS LEFT WITH THE CUSTOMER. Test in the following manner:

1.Close all doors and windows in the room / start

exhaust fans in the home / turn fireplace blower off (if equipped).

2. Set controls to "high" and light the unit.

3. Wait 5 minutes. Light a match and

 

extend it 1" into the hole located above

 

the spill switch bracket on the adapter.

 

4. Venting action is satisfactory if the

 

flame stays lit. Venting action is unsat-

FIGURE 40

isfactory if the flame extinguishes.

 

5.If venting action is unsatisfactory, turn the unit off, wait 10 minutes and try again. If the match does not stay lit, turn the unit off and check for vent blockage or restric- tion. If necessary, consult with a qualified inspector.

OPERATING INSTRUCTIONS

The on-off switch is located on the back of the unit at the top left corner on models GDS60 and GS60.

NOTE: The upper firebox baffle of your new cast stove has intentionally been left unpainted. Its shiny appear- ance will quickly transform to a dull black finish during the curing process.

When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventilate the room. After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ven- tilate the room.

OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Turn off all gas to the fireplace.

Open windows.

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.

W415-0158 / E / 02.19.04

Image 17
Contents For Your Safety Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information General InstructionsCare of GLASS, and Plated Parts Shipping BracketB C Location & ClearancesGDS60 and GS60 Venting Lengths AIR Terminal Locations Direct Vent Specifics Model GDS60AIR Terminal Installations 40 ft. maximum vertical run length 7 ft. horizontal run B Special Installation Example Offset Installation Example40 ft. maximum vertical run length Changing a TOP Vent to a Rear Vent Orifice ReplacementRear Vent Horizontal Termination Wall & Ceiling Protection Horizontal InstallationVenting Parameters Do not Fill this Space with ANY Type of Material Vertical Installation Horizontal Venting InstallationStove Vent Connection Vertical Venting InstallationMobile Home Installation Installing B Vent Chimney InstallationVent Specifics Model GS60 Vent Model GS60 onlyInstalling Flashing Adding Vent Sections GAS InstallationSolution. do not USE Open Flame Storm CollarRetainer Front Cast Installation Logo PlacementGlass Door Installation Removal FinishingLOG Placement Operating Instructions Operation / MaintenanceTo Turn OFF GAS MaintenanceLighting Instructions Adjustments Blower InstallationPilot Burner Adjustment Venturi AdjustmentIng information ReplacementsW415-0158 / E Symptom Problem Test Solution Trouble Shooting GuideModel GDS60 only Main burner flame is Model GDS60 onlyFireplace Service History

GDS60-N, GS60-N, GDS60-P, GS60-P specifications

Napoleon Fireplaces offers an impressive line of gas fireplaces, including the GDS60-N, GS60-N, GS60-P, and GDS60-P models, which represent the pinnacle of style, efficiency, and technology in modern heating solutions. These fireplaces are designed to enhance the comfort of your living space while ensuring an inviting atmosphere.

One of the standout features of the GDS60-N and GS60-N models is the unique Design and Style Series, which provides flexibility in customization. Homeowners can choose from a variety of finishes, including classic and contemporary styles, to seamlessly integrate the fireplace into their existing décor. The clean lines and elegant design make these units a focal point in any room.

Both models prioritize efficiency, boasting impressive heating capabilities that can warm spaces of significant size. They utilize advanced combustion technology, ensuring that heat is distributed evenly while maximizing fuel efficiency. The GDS60-P and GS60-P models offer similar features but come with a premium touch, providing enhanced aesthetics with their panoramic viewing area that showcases a mesmerizing flame display.

The burner system in these fireplaces is engineered for consistent performance, allowing users to enjoy the beauty of flickering flames with minimal maintenance. Innovative features such as the exclusive PHAZER log set provide a realistic fire effect, further enhancing the ambiance and visual appeal of the fireplace.

Additionally, Napoleon fireplaces incorporate top-tier safety measures, including an automatic shut-off feature, which ensures peace of mind for users. The intuitive remote control system enables easy temperature adjustments and flame settings, allowing for personalized comfort at the touch of a button.

Another notable characteristic is the easy installation process. These units are designed for both direct venting and conventional venting, offering versatility that caters to various home layouts. The manufacturers have placed a strong emphasis on craftsmanship, ensuring that each unit not only performs optimally but also lasts for years to come.

In conclusion, the Napoleon Fireplaces GDS60-N, GS60-N, GS60-P, and GDS60-P models epitomize the perfect fusion of technology, efficiency, and design. Homeowners looking for a reliable heating solution that doesn't compromise on style will find these gas fireplaces to be an excellent choice. With their captivating aesthetics, advanced features, and superior safety specifications, Napoleon continues to set a high standard in the fireplace industry.