Napoleon Fireplaces GDS60-N, GS60-P, GDS60-P Vertical Installation Horizontal Venting Installation

Page 11

VERTICAL INSTALLATION

11

HORIZONTAL VENTING INSTALLATION

This application occurs when venting through a roof.

Installation kits for vari- ous roof pitches are available from your Na- poleon dealer. See Ac- cessories to order the specific kit required.

FIGURE 20

FOR SAFE AND PROPER OPERATION OF THE STOVE, FOLLOW THE VENTING INSTRUCTIONS EXACTLY.

FOR HORIZONTAL RUNS, BOTH WOLF STEEL AND SIMPSON DURA-VENT VENTING COMPONENTS MAY HAVE A 0" RISE PER FOOT.

FOR OPTIMUM PERFORMANCE IT IS RECOM- MENDED THAT ALL HORIZONTAL RUNS HAVE A MINIMUM ¼ INCH RISE PER FOOT.

1.Determine the air terminal location and move the stove into position. Cut and frame 9 inch openings in the ceiling and the roof to provide the minimum 1 inch clearance be- tween the stove pipe and any combustible material. Try to

center the exhaust pipe location midway be- tween two joist to pre-

FIGURE 21vent having to cut them. Use a plumb bob to line

up the center of the openings.

DO NOT FILL THIS SPACE WITH ANY TYPE OF MATERIAL.

A vent pipe shield will prevent any materials such as insu- lation, from filling up the 1" air space around the pipe. Nail headers between the joist for extra support.

2.Apply a bead of caulking (not supplied) to the frame- work or to the Wolf Steel vent pipe shield plate or equiva- lent (in the case of a finished ceiling), and secure over the opening in the ceiling. A firestop must be placed on the bottom of each framed opening in a roof or ceiling that the venting system passes through. Apply a bead of caulking all around and place a firestop spacer over the vent shield to restrict cold air from being drawn into the room or around the stove. Ensure that both spacer and shield maintain the required clearance to combustibles. Once the vent pipe is installed in its final position, apply sealant between the pipe and the firestop spacer.

3.In the attic, after the pipe has been installed, slide the vent pipe collar down to cover

up the open end of the shield and tighten. This will prevent any materials, such as insulation, from filling up the 1" air space around the pipe.

FIGURE 22

1.Stretch the 4" diameter aluminum flexible liner to the required length taking into account the additional length needed for the finished wall surface.

Spacers are attached to the 4" inner flex liner at predeter- mined intervals to maintain a 1-1/4" air gap to the 7" outer stove pipe. These spacers must not be removed.

Slip a 4" diameter length of aluminum flexible liner a mini- mum of 2" over the inner sleeve of the air terminal. Secure to the sleeve using 3 screws. Seal the joint and screw heads using the high temperature sealant provided.

2.Slip the first section of 7" diameter stove pipe a mini- mum of 2" over the outer sleeve of the air terminal. Secure to the sleeve using 3 screws. Seal the joint and screw heads using high temperature sealant.

3.Insert the liners through the firestop / vent pipe shield. Holding the air terminal (lettering in an upright, readable position), secure to the exterior wall. Make weather tight by sealing with caulking (not supplied). The air terminal mount- ing plate may be recessed (up to 3/4" maximum) into the exterior wall or siding.

FIGURE 23

FIGURE 24

4.If more than one length of liner needs to be used to reach the stove, couple them together as illustrated in FIGURE 24. Seal the joints using the same procedure as described above.

The vent system must be supported approximately every 10 feet along a horizontal run. Use supports or equivalent non-combustible strapping to maintain the 1" clearance from combustibles.

W415-0158 / E / 02.19.04

Image 11
Contents For Your Safety Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Shipping Bracket General InstructionsGeneral Information Care of GLASS, and Plated PartsB C Location & ClearancesGDS60 and GS60 Venting Lengths AIR Terminal Locations Direct Vent Specifics Model GDS60AIR Terminal Installations 40 ft. maximum vertical run length 7 ft. horizontal run B Special Installation Example Offset Installation Example40 ft. maximum vertical run length Changing a TOP Vent to a Rear Vent Orifice ReplacementRear Vent Horizontal Termination Wall & Ceiling Protection Horizontal InstallationVenting Parameters Do not Fill this Space with ANY Type of Material Vertical Installation Horizontal Venting InstallationStove Vent Connection Vertical Venting InstallationMobile Home Installation Vent Model GS60 only Chimney InstallationInstalling B Vent Vent Specifics Model GS60Storm Collar Adding Vent Sections GAS InstallationInstalling Flashing Solution. do not USE Open FlameFinishing Logo PlacementRetainer Front Cast Installation Glass Door Installation RemovalLOG Placement Operating Instructions Operation / MaintenanceTo Turn OFF GAS MaintenanceLighting Instructions Venturi Adjustment Blower InstallationAdjustments Pilot Burner AdjustmentIng information ReplacementsW415-0158 / E Symptom Problem Test Solution Trouble Shooting GuideModel GDS60 only Main burner flame is Model GDS60 onlyFireplace Service History

GDS60-N, GS60-N, GDS60-P, GS60-P specifications

Napoleon Fireplaces offers an impressive line of gas fireplaces, including the GDS60-N, GS60-N, GS60-P, and GDS60-P models, which represent the pinnacle of style, efficiency, and technology in modern heating solutions. These fireplaces are designed to enhance the comfort of your living space while ensuring an inviting atmosphere.

One of the standout features of the GDS60-N and GS60-N models is the unique Design and Style Series, which provides flexibility in customization. Homeowners can choose from a variety of finishes, including classic and contemporary styles, to seamlessly integrate the fireplace into their existing décor. The clean lines and elegant design make these units a focal point in any room.

Both models prioritize efficiency, boasting impressive heating capabilities that can warm spaces of significant size. They utilize advanced combustion technology, ensuring that heat is distributed evenly while maximizing fuel efficiency. The GDS60-P and GS60-P models offer similar features but come with a premium touch, providing enhanced aesthetics with their panoramic viewing area that showcases a mesmerizing flame display.

The burner system in these fireplaces is engineered for consistent performance, allowing users to enjoy the beauty of flickering flames with minimal maintenance. Innovative features such as the exclusive PHAZER log set provide a realistic fire effect, further enhancing the ambiance and visual appeal of the fireplace.

Additionally, Napoleon fireplaces incorporate top-tier safety measures, including an automatic shut-off feature, which ensures peace of mind for users. The intuitive remote control system enables easy temperature adjustments and flame settings, allowing for personalized comfort at the touch of a button.

Another notable characteristic is the easy installation process. These units are designed for both direct venting and conventional venting, offering versatility that caters to various home layouts. The manufacturers have placed a strong emphasis on craftsmanship, ensuring that each unit not only performs optimally but also lasts for years to come.

In conclusion, the Napoleon Fireplaces GDS60-N, GS60-N, GS60-P, and GDS60-P models epitomize the perfect fusion of technology, efficiency, and design. Homeowners looking for a reliable heating solution that doesn't compromise on style will find these gas fireplaces to be an excellent choice. With their captivating aesthetics, advanced features, and superior safety specifications, Napoleon continues to set a high standard in the fireplace industry.