Napoleon Fireplaces GS60-N, GS60-P, GDS60-P Lighting Instructions, To Turn OFF GAS, Maintenance

Page 18

18

LIGHTING INSTRUCTIONS

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermo- couple has cooled. Allow approximately 60 seconds for the thermocouple to cool before attempting to re-light. When lighting and re-lighting, the gas knob cannot be turned from PILOT to OFF unless the knob is depressed.

1.STOP! Read the safety information on the operating label.

2.Turn off all electric power to the fireplace.

3.Turn the gas knob clockwise to off.

4.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor, STOP! Follow "B" on the op- erating label. If you don't smell gas go to the next step.

OL

 

 

 

N

O

H I

O

F

 

F

 

 

P

 

 

TO LI

TOLIP

 

 

5.Find pilot located in front of the back log.

6.Turn gas knob counter-clockwise to pilot.

7.Depress and hold the gas knob while lighting the pilot with the push button ignitor. Keep knob fully depressed for one minute, then release. If the pilot does not con- tinue to burn, repeat steps 3 through 6.

8.With the pilot lit, turn the gas knob counter-clockwise to on.

9.If equipped with a remote ON-OFF switch, main burner may not come on when you turn the valve to ON. The remote switch must be in the ON position to ignite the burner.

10.Turn on all electric power to the fireplace.

TO TURN OFF GAS

1. Turn off all electric power to the fireplace if service is to

2. Push in gas control knob slightly and turn clock-

be performed.

wise

 

to off. Do not force.

 

MAINTENANCE

TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER

BEFORE SERVICING THE STOVE!

CAUTION: Label all wires prior to disconnection when serv- icing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing. This stove and its venting system should be inspected before use and at least annually by a qualified service per- son. The fireplace area must be kept clear and free of com- bustible materials, gasoline or other flammable vapours and liquids. The flow of combustion and ventilation air must not be obstructed.

1. In order to properly clean the burner and pilot assem- bly, remove the logs exposing both assemblies.

2. Keep the control compartment, logs, burner, air shut- ter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.

4. Check to see that the pilot flames are large enough to engulf the thermocouple and the thermopile on one leg and reaches toward the burner on the other leg.

5. Replace the cleaned logs.

6. Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5-10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer/dis- tributor.

7.Check that the door gasketing is not broken or miss- ing. Replace if necessary.

W415-0158 / E / 02.19.04

Image 18
Contents For Your Safety Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Care of GLASS, and Plated Parts General InstructionsGeneral Information Shipping BracketLocation & Clearances GDS60 and GS60B C Direct Vent Specifics Model GDS60 Venting Lengths AIR Terminal LocationsAIR Terminal Installations Special Installation Example Offset Installation Example 40 ft. maximum vertical run length40 ft. maximum vertical run length 7 ft. horizontal run B Orifice Replacement Rear Vent Horizontal TerminationChanging a TOP Vent to a Rear Vent Horizontal Installation Venting ParametersWall & Ceiling Protection Vertical Installation Horizontal Venting Installation Do not Fill this Space with ANY Type of MaterialVertical Venting Installation Mobile Home InstallationStove Vent Connection Vent Specifics Model GS60 Chimney InstallationInstalling B Vent Vent Model GS60 onlySolution. do not USE Open Flame Adding Vent Sections GAS InstallationInstalling Flashing Storm CollarGlass Door Installation Removal Logo PlacementRetainer Front Cast Installation FinishingLOG Placement Operation / Maintenance Operating InstructionsMaintenance Lighting InstructionsTo Turn OFF GAS Pilot Burner Adjustment Blower InstallationAdjustments Venturi AdjustmentReplacements Ing informationW415-0158 / E Trouble Shooting Guide Symptom Problem Test SolutionModel GDS60 only Model GDS60 only Main burner flame isFireplace Service History

GDS60-N, GS60-N, GDS60-P, GS60-P specifications

Napoleon Fireplaces offers an impressive line of gas fireplaces, including the GDS60-N, GS60-N, GS60-P, and GDS60-P models, which represent the pinnacle of style, efficiency, and technology in modern heating solutions. These fireplaces are designed to enhance the comfort of your living space while ensuring an inviting atmosphere.

One of the standout features of the GDS60-N and GS60-N models is the unique Design and Style Series, which provides flexibility in customization. Homeowners can choose from a variety of finishes, including classic and contemporary styles, to seamlessly integrate the fireplace into their existing décor. The clean lines and elegant design make these units a focal point in any room.

Both models prioritize efficiency, boasting impressive heating capabilities that can warm spaces of significant size. They utilize advanced combustion technology, ensuring that heat is distributed evenly while maximizing fuel efficiency. The GDS60-P and GS60-P models offer similar features but come with a premium touch, providing enhanced aesthetics with their panoramic viewing area that showcases a mesmerizing flame display.

The burner system in these fireplaces is engineered for consistent performance, allowing users to enjoy the beauty of flickering flames with minimal maintenance. Innovative features such as the exclusive PHAZER log set provide a realistic fire effect, further enhancing the ambiance and visual appeal of the fireplace.

Additionally, Napoleon fireplaces incorporate top-tier safety measures, including an automatic shut-off feature, which ensures peace of mind for users. The intuitive remote control system enables easy temperature adjustments and flame settings, allowing for personalized comfort at the touch of a button.

Another notable characteristic is the easy installation process. These units are designed for both direct venting and conventional venting, offering versatility that caters to various home layouts. The manufacturers have placed a strong emphasis on craftsmanship, ensuring that each unit not only performs optimally but also lasts for years to come.

In conclusion, the Napoleon Fireplaces GDS60-N, GS60-N, GS60-P, and GDS60-P models epitomize the perfect fusion of technology, efficiency, and design. Homeowners looking for a reliable heating solution that doesn't compromise on style will find these gas fireplaces to be an excellent choice. With their captivating aesthetics, advanced features, and superior safety specifications, Napoleon continues to set a high standard in the fireplace industry.