16 | Document n° | |
TROUBLE SHOOTING |
| |
SYMPTOM | PROBLEM | TEST SOLUTION |
|
|
|
|
|
|
Flames extinguish during lighting. | Very cold chimney. No draft established | - leave door ajar until fire has caught. |
|
| - check air supply in the room |
Fire extinguishes once firestarter has | Fuel tank is empty | - fill tank |
burnt off. | Fuel valve is closed. | |
| ||
| Main carburetor float not engaging. | - |
|
|
|
| Control knob is set on “0" | - adjust control knob to ”1" |
|
|
|
Fire extinguishes during use. | Fuel tank is empty. | - fill tank |
|
|
|
| Insufficiant draft | - call your installer |
|
|
|
Flame is excessely large, smokey and | Fuel adjustment made too quickly. | - return control knob to “1"; wait for |
sooty. |
| normal combustion. (catalyser should |
|
| glow red) Wait 5 to 15 minutes between |
|
| each adjustment. |
|
|
|
Stove burns noisily, extinguishes and | Burner contains excess fuel | - adjust to lower setting. If problem |
relights itself. |
| persists call your installer. |
|
|
|
| Insufficient fuel | - check that the |
|
| carburetor filter and burner pot are |
|
| cleaned. |
|
|
|
Fire smokes.Soot build up noticed. | Insufficient air supply. | - increase fresh air supply (open door, |
Flame imbalance |
| window; add make up air supply) |
|
|
|
| Downdraft or blockage in chimney | - Check Chimney for Soot build up. |
|
| clean if necessary. |
|
| - ensure chimney height is sufficient |
|
| and cap is not affected by any nearby |
|
| obstructions. |
|
| - room is in negative pressure. Increase |
|
| fresh air supply. Check draft with draft |
|
| meter and adjust if not to requirements. |
|
| See page . |
| Oil flow is too low on 1 setting. | - adjust low flow rate while control is set |
|
| on “1", call your installer. |
|
|
|
| Stove is not level. Flame imbalance. | Check level. Adjust if necessary. |
|
|
|
| Catalyser not centered. Uneven fuel | Center catalyser assembly |
| distribution resulting in secondary air |
|
| shortage. |
|
|
|
|
Insufficient fuel
The draft regulator is blocked in open position
-check that the
-unlock the draft regulator.
-check the regulator adjustment (p. 10)
and refit, if necessary.
Coke build up noticed. | Excessive air supply. | - adjust draft. |