NuTone NP61000 manual Install the Ductwork, Install Mounting Brackets

Page 5

INSTALL THE DUCTWORK

NOTE: To reduce the risk of fire, use only metal ductwork.

1.Decide where the ductwork will run between the hood and the outside.

2.A straight, short duct run will allow the hood to perform most efficiently.

3.Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few of them as possible.

4.Install a roof or wall cap. Connect 6" round metal ductwork to cap and work back towards hood location. Use duct tape to seal the joints between ductwork sections.

INSTALL MOUNTING

BRACKETS

1.Construct wood wall framing that is flush with interior surface of wall studs.

Make sure:

a)the framing is centered over installation location.

b)the height of the framing will allow the mounting brackets to be secured to the framing within the dimensions shown.

2.After wall surface is finished, secure mounting brackets to framing using dimensions shown.

NOTE:

ROOF CAP

6” ROUND

 

 

DUCT

DECORATIVE

WALL

FLUE

CAP

 

HOOD

6” ROUND

 

 

ELBOW

24” TO 30” ABOVE

 

COOKING SURFACE

 

FRAMING BEHIND DRYWALL

 

 

 

5-7/8”

 

 

29

 

 

 

 

 

5-7/8”

13

 

 

 

 

 

 

 

/

to

 

 

 

 

cooktop

35

/

 

 

16

 

 

 

13

 

 

 

 

 

 

 

 

above

 

 

 

 

 

16

 

2913/16"=bottom of hood 24" above cooktop 3513/16"=bottom of hood 30" above cooktop

-On 8’ ceilings, the hood distance above cook top is : minimum 24”, maximum 27-1/2”.

-On 9’ ceilings, the hood distance above cook top is :

-minimum 27”, maximum 30” (for Ducted Configuration).

-minimum 24”, maximum 30” (for Non-Ducted Configuration).

- 5 -

Image 5 Contents
Français Español NP61000 SeriesIntended for Domestic Cooking only ! Warning Read and Save These InstructionsPage Prepare the Hood Install Mounting Brackets Install the DuctworkWiring Install the HoodConnect Ductwork Ducted ConfigurationFlat-head screws 2.9x13mm Ductfree Filter InstallationHood Cleaning MaintenanceGrease Filters Ductfree FiltersControls OperationHalogen Bulbs Switch OFF the Electricity Supply Fuse ReplacementWarranty Avertissements Seulement Pour Utilisation Domestique ! AvertissementsPage Preparez LA Hotte Installation DES Etriers D’ASSEMBLAGE Installation DU Systeme D’EVACUATIONInstallation Electrique Installation DE Votre HotteModèle avec tuyau d’évacuation Connexion DU Systeme D’EVACUATIONModèle recyclant l’air Assemblage DU FiltreFiltres anti-graisse EntretienFiltres pour modèles recyclant l’air Nettoyage de votre hotteFonctionnement CommandesAmpoules Halogenes AvertissementDÉBRANCHEZL’APPAREIL Remplacement FusibleGarantie Advertencia LEA Y Conserve Estas InstruccionesAdvertencia Montaje 2,9x13mm cabeza plano Prepare LA CampanaInstalacion DE LOS Soportes Para EL Montaje Instalacion DEL Tubo DE ExtraccionInstalacion Electrica Instalacion DE LA CAMPA- NAEntubado DE Canalizacion Configuración con tuboInstalacion DEL Filtro Configuración sin tuboMantenimiento Filtros configuración sin tuboFiltros antigrasa Limpieza de la campanaLamparas Halogenas FuncionamientoMandos Heat SentrymrDesconectarelaparato Sustitucion FusibleGarantia Keyno Description Service PartsPart N Description Liste Pieces DE RechangeCÓD. N Pieza N Descripción Lista DE Piezas DE RecambioNP61000 Series Range Hood 04307652/1N