INSTALL THE HOOD
3.Remove the tape located on the damper.
4.Hang the hood from the brackets through the rectangular
The bottom of the hood should be 24" to 30" above the cooking surface.
5.Height adjustment screws provide vertical adjustment.
6.Depth adjustment screws provide horizontal adjustment.
7.Secure the hood with mounting screws (4.8x38mm). Use drywall anchors, provided, if wall studs or framing are not available.
WIRING
Note: This range hood must be properly grounded. The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes.
1.Remove the wiring box cover. Remove a knockout from the wiring box.
2.Secure the conduit to the wiring box through a conduit connector.
3.Make electrical connections. Connect white to white, black to black and green to green.
4.Replace wiring box cover and screws. Make sure that wires are not pinched between cover and box.
-6 -
REMOVE THE TAPE
RECTANGULAR CUTOUTS
MOUNTING
BRACKETS
MOUNTING
SCREWS
(4.8x38mm)
WALL FRAMING
DEPTH ADJUSTMENT
SCREWS
HEIGHT
ADJUSTMENT
SCREWS
MOUNTING
SCREWS
(4.8x38mm)
WIRING BOX
COVER
DUCT
COLLAR