Pitco Frialator E500D, E400T operation manual Trouble Shooting, Troubleshooting

Page 14

TROUBLE SHOOTING

TROUBLESHOOTING

Should there be a problem with your appliance, use the following tables to isolate possible faults before calling your Authorized Service Agent.

Check these items before calling your Authorized Service Company.

 

ITEM TO CHECK

HOW TO CHECK

 

Power to appliance

Check main power breaker to appliance.

 

Hi-Limit reset

Press Hi-Limit reset button..

 

 

 

 

 

Power switch on

Power switch should be in the ON ( I ) position.

 

 

 

 

 

COOK SYSTEM TROUBLESHOOTING

 

 

SYMPTOM

POSSIBLE CAUSES

 

 

Appliance will not run, front panel lights are not on.

Check main power breaker to appliance, blown

 

 

control fuse, faulty transformer.

 

 

 

 

 

Appliance will not run, front panel lights are on.

Tripped hi-limit, faulty temperature probe, faulty

 

 

temperature control.

 

 

 

 

 

Appliance will not maintain temperature properly

Faulty temperature probe, faulty hi-limit switch

 

 

 

 

 

 

 

 

 

FILTERING SYSTEM TROUBLESHOOTING

 

SYMPTOM

POSSIBLE CAUSES

 

 

Filter system will not operate

Filter switch/circuit breaker is in the OFF ( O )

 

 

position

 

 

 

 

 

Filter system will not operate, filter switch/circuit

Thermal cutout on filter pump is tripped, faulty

 

 

breaker is in the ON ( I ) position.

filter switch/circuit breaker, faulty filter pump.

 

 

 

Filter paper is dirty, filter pickup is clogged with

 

 

Filter system runs, but does not return shortening to

debris, filter line strainer is clogged with debris,

 

 

tank.

filter return line is clogged with debris, faulty filter

 

 

 

pump

 

 

Filter system runs but returns shortening very

Filter pickup tube is not properly seated, air leak in

 

 

slowly or blowing air into tank.

filter system, faulty filter pump.

 

L20-258-UK Rev.01 8/16/04

11

Image 14
Contents E400, E400T and E500D For Your Safety Table of Contents Checking Your NEW Pitco Appliance AssemblyLeg/Caster Installation and Leveling Electrical Connection InstallationInstallation Clearances Initial Cleaning Types of Fire Extinguishers and Detection EquipmentFilling the tank with solid shortening/oil Filling the TankFilling the tank with liquid shortening/oil Operating InstructionsAppliance Start-Up Appliance Shut-down Filtering InstructionsFilter Paper Replacement Filtering InstructionsWeekly Cleaning Daily CleaningFilter Pan and Filter Pickup Assembly Cleaning Boil Out ProcedureFilter System Cleaning Thermostat Calibration Check Thermostat CalibrationTrouble Shooting TroubleshootingL20-258-UK Rev.01 8/16/04 L20-258-UK Rev.01 8/16/04 L20-258-UK Rev.01 8/16/04 L20-258-UK Rev.01 8/16/04 L20-258-UK Rev.01 8/16/04 L20-258-UK Rev.01 8/16/04