INSTALLATION

INSTALLATION

If you have completed the above steps that are applicable to the appliance you purchased, the appliance is now ready to be installed. Although it may be possible for you to install and set up your new appliance, it is STRONGLY recommended that you have this done by qualified professionals. A qualified professional will ensure that the installation is safe and meets local building and fire codes.

Installation Clearances

The clearances shown below are for combustible and non-combustible installations and will allow for safe and proper operation of your appliance.

 

Combustible

Non-

 

Combustible

 

Construction

 

Construction

 

 

Back

0

0

Sides

0

0

Floor

4 ¾ (12 cm)

4 ¾ (12 cm)

In addition to the above clearances there must also be at least 28 inches of aisle space in front of the unit for the removal/installation of the filter pan.

Electrical Connection

Your Pitco appliance is manufactured to operate on a particular electrical supply. DO NOT attempt to connect the appliance to an electrical supply other than that indicated on the data plate. Electrical connection should be performed by qualified personnel.

The electrical connection used by this appliance must comply with local codes. If there are no local codes that apply, refer to the National Electrical Code (NEC), ANSI/NFPA 70 for installation in the US. In Canada, refer to CSA Standard C22.1 and local codes. In all other cases, refer to local and national codes and regulations.

The appliance must be grounded in accordance with local code; if there is no local code, comply with NEC ANSI/NFPA No. 70 latest edition (for US and Canadian installations). In all other cases, refer to local and national codes and regulations. To comply with European requirements, European models are equipped with an equalization-bonding clamp. An equalization bonding lead must be connected to this clamp to provide sufficient protection against potential difference. This clamp, located on the rear of the appliance is marked with the following universal symbol.

Ventilation and Fire Safety Systems

Your new appliance must have proper ventilation to function safely and properly. It is very important to install a fire safety system. Your ventilation system should be designed to allow for easy cleaning. Frequent cleaning and proper maintenance of the ventilation system and the appliance will reduce the chances of fire. The following tables contain a list of reference documents that will provide guidance on ventilation and fire safety systems. It is not necessarily complete. For US and Canada, additional information can be obtained from CSA International, 8501 East Pleasant Valley Road, Cleveland, OH, 44131 or visit their website at www.csa-international.org.

Hoods and Ventilation Systems

TOPIC

UL Document

National Fuel Gas

Code Document

 

 

Exhaust Hoods

ANSI/UL 70

ANSI/NFPA 96

Power Ventilators

ANSI/UL 705

ANSI/NFPA 96

Filter Units

ANSI/UL 900

ANSI/NFPA 96

2

L20-258-UK Rev.01 8/16/04

Image 5
Contents E400, E400T and E500D For Your Safety Table of Contents Checking Your NEW Pitco Appliance AssemblyLeg/Caster Installation and Leveling Electrical Connection InstallationInstallation Clearances Types of Fire Extinguishers and Detection Equipment Initial CleaningFilling the tank with liquid shortening/oil Filling the TankFilling the tank with solid shortening/oil Operating InstructionsAppliance Start-Up Filtering Instructions Appliance Shut-downFiltering Instructions Filter Paper ReplacementFilter Pan and Filter Pickup Assembly Cleaning Daily CleaningWeekly Cleaning Boil Out ProcedureFilter System Cleaning Thermostat Calibration Thermostat Calibration CheckTroubleshooting Trouble ShootingL20-258-UK Rev.01 8/16/04 L20-258-UK Rev.01 8/16/04 L20-258-UK Rev.01 8/16/04 L20-258-UK Rev.01 8/16/04 L20-258-UK Rev.01 8/16/04 L20-258-UK Rev.01 8/16/04