Proline PLFW544, PLFI750, PLFW812, PLFI543 Wall Hood Installation, Install anchors and screws

Page 13

USER manual  9

WALL HOOD INSTALLATION

Plan where the ductwork will be located. Install proper-sized duct work, and roof or wall cap, depending on where you will be venting your hood. Recommended and most com- mon installations are shown in the venting diagrams above. Adjust your measurements to accomodate heights of ceilings, cabinets, or rangetops.

STEP 1 Install anchors and screws

Markings you’ll need:

♦♦ center line of installation area ♦♦ location of studs

♦♦ horizontal line 28” - 36” above the cook top (this is where the bottom of the range hood will be)

Use one panel of the cardboard ship- ping box to trace an outline of the hood.

♦♦ Place the cardboard panel against the range hood and trace an outline

♦♦ Find the center point of range hood (di- rectly between mounting holes) and mark it on the cardboard panel

♦♦ Find the mounting points on the hood and mark them on the panel

♦♦ Transfer the panel to the wall, lining the bottom of panel to the horizontal line

♦♦ Line up the center point of the panel with center point on the wall

♦♦ Find mounting points on the cardboard and poke holes through it, marking where you will mount the hood to the wall.

♦♦ Predrill holes where your mounting marks are, then insert wall anchors and mount- ing screws

Image 13
Contents Proline Proline Customer Support Team Table of Contents Important Safety Notice To reduce the risk of a range top grease fire Wall or Island Hood Control Panel PowerSpeeds Automatic Fan ShutoffBaffle filter Grease FiltersCharcoal filter Ductless FiltersHorizontal Wall Venting Venting OptionsVertical Roof Venting OptionHeight & Venting Requirements Venting RequirementsInspect Range Hood PreparationTools YOU’LL Need Prepare DuctworkInstall anchors and screws Wall Hood InstallationHang hood and connect Install ceiling bracketInstall grease filter Install chimneyStep Island Hood InstallationIsland Hood Installation Hood Insert Installation Hood Insert Installation Cleaning Exterior Surfaces Care & CleaningReplacing the Light Bulb Removing the filterNothing Works Control Panel not lit, Blower not working TroubleshootingTwo Year Warranty Parts & Labor WarrantyOne Year Warranty Parts Only What is not CoveredUpon Receipt of Your Hood ReturnsReturns Exchanges ExchangesReturn Claims not Accepted if Please NoteProline Range Hoods

PLFI520, PLFW750, PLFL832, PLFW520, PLFI544 specifications

Proline's PLFI750, PLFW544, PLFW832, PLFI543, and PLFL832 are a series of advanced flow measurement instruments designed for accurate flow monitoring in various industrial applications. Each model offers unique features and technological advancements that cater to specific measurement needs within the industry.

The PLFI750 is renowned for its high accuracy and robustness. It employs a magnetic flow measurement principle, making it suitable for conductive liquids. With a wide measurement range and low-pressure loss, the PLFI750 ensures high efficiency and reliability in chemical and water treatment applications. Its built-in diagnostics and user-friendly interface facilitate easy setup and monitoring.

The PLFW544 model is a versatile inline flow meter specifically designed for wastewater and slurry applications. It features a non-intrusive design that ensures minimal maintenance. The PLFW544 is equipped with advanced signal processing technology, enabling it to handle challenging media with varying densities and viscosities without compromising measurement accuracy.

For applications requiring advanced data analysis, the PLFW832 stands out with its integrated Bluetooth technology. This model supports wireless data transmission, allowing users to monitor flow measurements remotely via a smartphone or tablet. The PLFW832 also features a large, bright display that shows real-time readings and operational status, enhancing usability in field environments.

The PLFI543 is tailored for precise flow measurement in the food and beverage industry. It includes hygienic design features such as smooth surfaces and easy-to-clean components that comply with food safety regulations. This model's ability to handle high-pressure and temperature conditions further extends its applicability in demanding scenarios.

Last but not least, the PLFL832 offers a unique combination of versatility and advanced fluid characteristics measurement capabilities. Its multi-parameter detection can measure flow, temperature, and pressure simultaneously, providing comprehensive insights into operation conditions. The PLFL832's robust design ensures it can withstand harsh environmental conditions, making it suitable for oil and gas applications.

In summary, Proline's PLFI750, PLFW544, PLFW832, PLFI543, and PLFL832 models each bring distinct advantages, from advanced diagnostics to hygienic compliance and multi-parameter detection. These technologies and characteristics make them suitable for diverse applications, from chemical processing to food production, thus positioning Proline as a leader in flow measurement solutions.