Threshold Limit
Threshold Limit
OSHA Limits vs ACGIH Guidelines: OSHA limits are legally enforceable, whereas ACGIH limits are guidelines. In most cases, the ACGIH guidelines are the same or lower than OSHA limits (there are a few exceptions). When the values are not the same, it is prudent to follow the lower, more conservative value.
Examples:
Chemical | OSHA | ACGIH | |
PEL | TLV | ||
| |||
Acetic acid | 10 ppm | 10 ppm | |
|
|
| |
Ammonia | 50 ppm | 25 ppm | |
|
|
| |
Formaldehyde | 0.75 ppm | 0.3 ppm | |
|
| (ceiling) | |
|
|
| |
Sulfur dioxide | 5 ppm | 2 ppm | |
|
|
|
METHODS OF
EVALUATION
THE PURPOSE OF
COLLECTING AIR
SAMPLES
Air samples are sometimes collected to evaluate potential worker exposure levels for comparison to published exposure standards or guidelines. The purpose of the
measurement may vary depending on whether you are interested in
Figure 1
Typical Exposure Scenario
|
|
|
| Actual |
Concentration (ppm) |
| OSHA PEL |
| |
|
|
| Avg. | |
|
|
|
| |
8am | 10am | Noon | 2pm | 4pm |
Basic Definitions
Sensitivity or Precision: how
reproducible is the sampling method.
Accuracy: how close to the true value is the sampling method.
MEASUREMENT
TECHNIQUES
Direct Reading
These are measurement techniques that can immediately indicate the concentration of aerosols, gases, or vapors by some means such as a dial or meter or noting the color change of an indicator chemical.
Colorimetric Detector Tubes Several colorimetric, direct reading detector tubes are useful for quick assessments of airborne contaminants associated with photographic processing. A special pump draws a specific volume of room air through a detector tube. If the contaminant is present, a color change occurs along the length of the tube that is directly proportional to the concentration of the contaminant in the air. Tubes are available for acetic acid, sulfur dioxide, ammonia, and many other gases and vapors. The tubes are easy to use and generally have an accuracy of ± 25%. Other chemicals in the air may interfere with the accuracy and sensitivity of the tubes.
Indoor Air Quality and Ventilation in Photographic Processing Facilities • | 5 |