Polycom EF2241 manual Device IDS on the EF BUS, Connecting Multiple Vortex Devices

Page 12

INSTALLATION

Connect speaker output to loudspeaker.

If RS-232 remote control is desired, connect the RS-232 REMOTE CONTROL port of the EF2241 to the remote control device, such as an RS-232 interface to a touch panel or a COM port on a personal computer.

Connect the LINE RJ11 jack to an analog telephone line.

Connect the PHONE RJ11 jack to an analog telephone set (optional).

Connect the external power supply to the POWER SUPPLY INPUT jack of the EF2241.

Set the country code on the EF2241. By default the phone interface will be dis- abled until you select a country code for the telephony interface. This can either be done with the front panel LCD menu, or the RS-232 interface. The country code only needs to be selected the first time or when the country of the installa- tion is changed.

DEVICE IDS ON THE EF BUS

When considering which Device IDs can be used for which Vortex device, decide how many devices have the ability to transmit on the W, X, Y, and Z busses, and how many have the ability to transmit on the P Bus. The EF2280, for example can only transmit on the W, X, Y, and Z busses while the EF2241 can transmit on the W, X, Y, and Z busses as well as the P bus. Up to 8 devices can transmit on the W, X, Y, and Z busses. Similarly, up to 8 devices can transmit on the P bus. Note that the EF2241 counts as one of both types. All devices that can transmit on W, X, Y, and Z must have unique device IDs. Vortex devices of the same type must have unique device IDs. If the device IDs of linked Vortex devices are the same, the front panel LCD screen will display “EFBus Error: Dev. ID Conflict”.

CONNECTING MULTIPLE VORTEX DEVICES

Up to 8 Vortex devices in combination can be linked together at one time (See Device IDs on the EF Bus above). Each unit in the chain must have a unique Device ID. Use the EF Bus to link multiple Vortex devices together.

The following steps should be followed to connect the EF Bus:

1.Set a unique Device ID for each Vortex device. The Device IDs range from 00 to 07.

2.Power off all units.

3.Connect the RS-232 remote control device to any Vortex device in the chain.

4.Connect the provided Cat-5 cable between the EF BUS OUT of the first device, and the EF BUS IN of the second device.

Note. The EF Bus must be connected so that the EF Bus In of one

box is connected to the EF Bus Out of another. Connecting the EF Bus In to another EF Bus In (or Out to Out) will not work.

5.Connect another Cat-5 cable between the EF BUS OUT of the second device and the EF BUS IN of the third device, and so on.

6.Power on all units at the same time.

VORTEX EF2241 Reference Manual

10

Technical Support: 800.932.2774

Image 12
Contents Vortex EF2241 Reference Manual Page Introduction Welcome How to Use This Manual IntroductionProduct Features Product RegistrationProduct Inputs Outputs Remote Control PRE-INSTALLATION Tools Needed for InstallationWhat’s Included What’s Not IncludedEF2241 Front and Rear Panels PRE-INSTALLATION Installation Connecting the EF2241 to Other EquipmentMounting the EF2241 North American RequirementTypical EF2241 Connections CodecConnecting Multiple Vortex Devices Device IDS on the EF BUSFactory Default Settings Preset Terminating the EF2241Off Presets Multiple Vortex Devices Pick a Standard Signal LevelCheck Surrounding Equipment Configure Program Audio Sources Input Settings Integrating the EF2241 Into Your SystemCalibration Set Levels on Line Input Channels SET UP the Phone Interface Build Your Echo Canceller ReferenceEcho Canceller Reference for Multiple Vortex Devices Customize Setting for Your Particular ApplicationSetting up Bus ReferenceConfigure the Automatic Microphone Mixer Automixer ParametersGlobal Settings Automixer Settings for Multiple Vortex Devices Channel SettingsConfigure the Matrix Mixer Default SettingsBuilding Your System with Multiple Vortex Devices Configure the submatrix Assign Inputs Assign OutputsEF BUS Presets Other EF2241 FeaturesConfigure Your Echo Canceller Reference LCD Menu Structure LCD Menu TreeLCD Menu Structure System Menu SystemPhone Control Phone ControlInputs Inputs 1-4, T, A-DOutputs Automixer MenuGlobal Settings Mixer Settings Matrix Menu MatrixParametric EQ Menu Input/Output EQ Channel BandPresets MacrosTroubleshooting Automatic Microphone MixerNo microphones are gating Some microphones are not gating Too many microphones are gatingEcho Canceller Reference Matrix MixerResidual Echo Room Audio Sounds ChoppyFinding the Source of Echo Room Gain Excessive Room Gain Room GainIn-Conference Quick Check Excessive Microphone Amplification Insufficient NonlinearityContacting Technical Support Email vortex@polycom.comTechnical Specifications Compliance USA and CanadaUS Telco requirements Automatic Dialing Telco Connector Canadian Telco RequirementsAustralia Rest of WorldThis page was intentionally left blank CE Mark R& TTE Directive Vortex EF2241 Reference Manual Technical Support Conference System Design Noise and Reverberation Consider Room GainEF2241 Block Diagram EN Echo Canceller, Noise CancellerConnector Pinouts EF BusInput/Output Remote Control Port Connecting Unbalanced RCA to Balanced Mini Phoenix Making AN EF BUS TerminatorInstructions Additional Notes Warranty Information RMA# Must be on packageWhat this warranty does not cover State Law RightsEcho Canceller Definition of TermsAcoustic Echo Crosspoint Mix Minus BusNOM Attenuation NOM Bus Presets Room Gain NOMDefinition of Terms Index NOM Index Page 1725-80098-001-C