Polycom EF2241 manual Connector Pinouts, EF Bus

Page 55

CONNECTOR PINOUTS

CONNECTOR PINOUTS

EF BUS IN

8 1

1 8

EF BUS OUT

8 1

Cat 5 Plug

(Front View)

REMOTE CONTROL

5 1

96

RS-232

EF Bus

The EF Bus uses RJ45 connectors. These should be used with category five twisted-pair cable.

The total distance of the EF Bus should be less than 4.5 m.

The EF Bus must be connected so that the EF Bus In of one box is connected to the EF Bus Out of another. Connecting the EF Bus In to another EF Bus In (or Out to Out) will not work.

Cat-5 Plug Pinout

1 - White/Orange

2 - Orange

3 - White/Green

4 - Blue

5 - White/Blue

6 - Green

7 - White/Brown

8 - Brown

RJ11 Plug Pinout

3 - Ring

4 - Tip

Note: Other pins are not connected. The DAA is not affected by Tip and Ring wiring reversal.

RS-232 Port (9600, 19200, 38400, 8-N-1)

The RS-232 port is wired as DCE. It accepts a male DB-9 connector. Only pins 2, 3, and 5 are required by the EF2241 but pins 7 and 8 are supported. Con- nect pins straight through (do not use null modem). 1 DCD; 2 TXD; 3 RXD 4 DSR; 5 ground; 6 DTR; 7 CTS; 8 RTS; 9 No connection

Baud rate is selectable at 9600, 19200, or 38400.

© Polycom, Inc.

51

VORTEX EF2241 Reference Manual

Image 55
Contents Vortex EF2241 Reference Manual Page Introduction Introduction Welcome How to Use This ManualProduct Registration Product FeaturesProduct Inputs Outputs Remote Control What’s Not Included PRE-INSTALLATIONTools Needed for Installation What’s IncludedEF2241 Front and Rear Panels PRE-INSTALLATION North American Requirement InstallationConnecting the EF2241 to Other Equipment Mounting the EF2241Codec Typical EF2241 ConnectionsDevice IDS on the EF BUS Connecting Multiple Vortex DevicesTerminating the EF2241 Factory Default Settings PresetOff Pick a Standard Signal Level Presets Multiple Vortex DevicesCheck Surrounding Equipment Configure Program Audio Sources Integrating the EF2241 Into Your System Input SettingsCalibration Set Levels on Line Input Channels Customize Setting for Your Particular Application SET UP the Phone InterfaceBuild Your Echo Canceller Reference Echo Canceller Reference for Multiple Vortex DevicesBus Reference Setting upAutomixer Parameters Configure the Automatic Microphone MixerGlobal Settings Channel Settings Automixer Settings for Multiple Vortex DevicesDefault Settings Configure the Matrix MixerBuilding Your System with Multiple Vortex Devices Assign Inputs Assign Outputs Configure the submatrixEF BUS Other EF2241 Features PresetsConfigure Your Echo Canceller Reference LCD Menu Tree LCD Menu StructureLCD Menu Structure System System MenuPhone Control Phone ControlInputs 1-4, T, A-D InputsAutomixer Menu OutputsGlobal Settings Mixer Settings Matrix Matrix MenuInput/Output EQ Channel Band Parametric EQ MenuMacros PresetsToo many microphones are gating TroubleshootingAutomatic Microphone Mixer No microphones are gating Some microphones are not gatingRoom Audio Sounds Choppy Echo Canceller ReferenceMatrix Mixer Residual EchoFinding the Source of Echo Room Gain Room Gain Excessive Room GainIn-Conference Quick Check Excessive Microphone Amplification Nonlinearity InsufficientEmail vortex@polycom.com Contacting Technical SupportTechnical Specifications USA and Canada ComplianceUS Telco requirements Canadian Telco Requirements Automatic Dialing Telco ConnectorRest of World AustraliaThis page was intentionally left blank CE Mark R& TTE Directive Vortex EF2241 Reference Manual Technical Support Noise and Reverberation Consider Room Gain Conference System DesignEN Echo Canceller, Noise Canceller EF2241 Block DiagramEF Bus Connector PinoutsInput/Output Remote Control Port Making AN EF BUS Terminator Connecting Unbalanced RCA to Balanced Mini PhoenixInstructions Additional Notes RMA# Must be on package Warranty InformationState Law Rights What this warranty does not coverCrosspoint Mix Minus Bus Echo CancellerDefinition of Terms Acoustic EchoNOM NOM Attenuation NOM Bus Presets Room GainDefinition of Terms Index NOM Index Page 1725-80098-001-C