Preparation before Installation

Preparation before Installation

Figure 1

NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING.

￿Decide the location of the venting pipe from the hood to the outside. (Figure 1)

￿A straight, short vent run will allow the hood to perform more efficiently.

￿Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the

hood.

￿ Temporarily wire the hood to test for Figure 2 proper operation before installing. Refer

to figure 5 on page 6.

￿Important: Peel protective film off the hood and duct covers, if any.

￿Use duct tape to seal the joints between pipe sections.

Advance Planning

1.Mark centerlines of cook top or range on ceiling. Use centerlines marked on ceiling to position the mounting template as shown in Figure 2.

2.Remove and save template. Cut and remove ceiling drywall. Install 2” x 4” cross framing lumber (not provided) between ceiling joists.

3. The framing should be spaced 12-1/8” at the

Figure 3

front centerline and 14-1/4” on the sides to

 

accept the

mounting screw in the

 

telescopic

stack.

Refer

to

 

MEASUREMENTS

& DIAGRAMS

on

 

pages 14-15. Shown in Figure 3.

 

 

4.Finish the ceiling surface. Be sure to mark the location of the ceiling joists and cross framing lumber.

5.Align the mounting template to the ceiling marks and tape in place. Cut the 7-1/4” duct open and approximately 1” wire access hole. Drill holes for the 8 mounting screws as indicated on the template.

5

Image 7
Contents Model No. IS2436GSB IS2442GSB IS-124 SERIES KOBE Brand Range Hood“ISLAND GLASS CANOPY WITH LCD SCREEN” READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING CONTENTSALL WIRING MUST BE DONE BY A PROFESSIONAL AND IN READ AND SAVE THESE INSTRUCTIONSPLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION IMPORTANT SAFETY INSTRUCTIONSWhat to Do In The Event Of a Range Top Grease Fire Must keep all material for returns or refunds COMPONENTS OF PACKAGEBOX 1 OF MODEL NO. IS2436GSB MODEL NO. IS2442GSB BOX 2 OF MODEL NO. IS124DCBottom Recommended 30” to 36” SAFETY WARNINGINSTALLATION C = Preferred Height of Counter Top to HoodAdvance Planning Preparation before InstallationImportant Peel protective film off the hood and duct covers, if any Wiring to Power Supply Telescopic Stack InstallationDuctwork Installation Final Assembly Duct Cover InstallationConnection to LCD Screen LCD DISPLAY OPERATION INSTRUCTIONS1. Press until flashes When appears, keypad sound is ONTurning Lights ON Setting Delay ModeSetting Timer Mode Turning ISC Integrated Sensor Control ON/OFFTo Clean or Replace Baffle Filter MAINTENANCETo Clean Hood Surface CAUTION NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHSCAUTION HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL To Replace Light BulbSPECIFICATIONS Sold Separately MEASUREMENTS & DIAGRAMSMODEL NO. IS2442GSB PARTS LISTBox 1 of MODEL NO. IS2436GSBOPTIONAL MODEL NO. IS2436GSB IS2442GSBBOX 1 OF 2 - GLASS CANOPY WITH LCD SCREEN BOX 2 OF 2 - DUCT COVERCIRCUIT DIAGRAM CLAIMS WILL NOT BE ACCEPTED AFTER THE ALLOCATED DAYS DISCLAIMERDAMAGES CAUSED DURING TRANSIT ARE NOT COVERED UNDER OUR WARRANTY 2. PLEASE INSPECT CONTENTS OF PACKAGE S CAREFULLY UPON RECEIPTCONDITIONS WARRANTYWARRANTY CERTIFICATE TWO-YEAR WARRANTY SERVICE PERIODCONSEQUENTIAL DAMAGE SERVICEIMPLIED WARRANTIES/STATE LAW Register Your Product PRODUCT REGISTRATIONRECORD THE FOLLOWING INFORMATION FOR YOUR RECORD KOBE Range Hoods 10505 Valley Blvd Suite # El Monte, CA 91731 USA