How to Use the Vent Graph

The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system.

1.Determine the height of the center of the horizontal vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph bellow, locate the point intersecting with slanted graph line.

2.From the point of this intersection, draw a vertical line to the bottom of the graph.

3.Select the indicated dimension, and position the fireplace in accordance with same.

Example A:

If vertical dimension from floor of the fireplace is 11’ (3.4 m), horizontal run to the face of outer wall must not exceed 14’ (4.3 m).

Example B:

If vertical dimension from floor of the unit is

7’ (2.14 m), horizontal run to the face of outer wall must not exceed 8¹⁄’ (2.6 m).

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vertical dimensionfromflooroftheunit to center of thehorizontalventpipe

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

eg: A

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

eg: B

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

DV Graph

 

Horizontal dimension from outside of the wall

to the center of the fireplace vent flange

Sidewall vent graph showing the relationship between vertical and

horizontal dimensions for a Direct Vent flue system.

Fig. 16 Sidewall vent graph.

360DVS Series Direct Vent Fireplaces

Rear Wall Application

When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall

behind the appliance.

Specific rear vent starter kits must be used in these applications (see ‘venting components’). The appli- ance has been approved for installation flat against a rear wall. (Fig. 17)

Maximum horizontal distance between the rear of the appliance and the outside face of the rear wall is 20” (508 mm). (Fig. 17)

Minimum clearances between any combustible ma- terial and the vent pipe sections are:

Top

 

2” (51 mm)

Sides

 

1” (25 mm)

Bottom

 

1” (25 mm)

 

 

 

 

 

 

Max. 20” (508mm)

FP1434

Fig. 17 Rear vent application.

Rear Wall Installation

Step 1

Locate and cut vent opening in the rear wall.

Combustible walls: Cut a rectangular hole measuring 10³⁄” H x 9³⁄” W (265 x 240 mm) through the exterior wall and frame. Frame in the opening per Figure 18.

Noncombustible walls: Cut a round hole measuring 7¹⁄” (190 mm) diameter through the exterior wall and frame. (Fig. 18)

STEP 2

For combustible walls: Measure wall thickness and cut zero clearance sleeve parts to proper length.

Max. length is 12” (305 mm). Assemble sleeve to its maximum opening of 10³⁄” x 9³⁄” (265 x

240 mm), and attach to firestop with #8 sheetmetal screws (supplied). Install firestop assembly. (Fig. 19)

NOTE:Zero clearance sleeve is required only for com- bustible walls.

10006326

15

Image 14
Contents 360DVSL 360DVSR Locating Your Fireplace Please Review the Following CarefullyTop Vent Configuration Fireplace Dimensions 360DVS2Rear Vent Configuration Fireplace Dimensions 360DVS3 / 306DVSL / 360DVSR Configuration Framing Dimensions 360DVS2Rear Vent Rear Vent Configuration Top Vent ConfigurationRear Vent Configuration Top Vent Configuration Model 360DVS3 Framing Dimensions 360DVS3 / 360DVSL / 360DVSRRear Vent Confiration 360DVSL/RHearth Clearance to CombustiblesMantels Final Finishing Gas Line InstallationFraming & Finishing Gas SpecificationsEB-1 Electrical Junction Box Connection Remote ON/OFF Switch InstallationAlternate Switch Location Alternate switch location Optional Top Vent ApplicationLocation of Vent Termination Electronic Gas Control ValveThere must not be any obstruction such as bushes Canadian Installations US Installations General Venting Information Termination LocationGeneral Information Assembling Vent Pipes Canadian InstallationsUSA Installations Twist Lock PipesRear Wall Application How to Use the Vent GraphRear Wall Installation StepVertical Sidewall Application Locate vent opening on rear wallVertical Side Wall Installation Zero clearance sleeve is required only for combustible wallsAlways install horizontal venting on a level plane Vertical height requirementBelow Grade Installation Horizontal runs if the vertical exceeds 24 610 mmMaximum termination to roof clearance Vertical Through-the-Roof Installation Chimney supportTwist Lock Venting Components Glass Information Window Frame Assembly RemovalFront Window Frame Assembly Louvre RemovalLog Installation Glass CleaningCeramic Refractory Installation Ember Material Pt. #51915 Lava Rock and Ember Material PlacementFlame & Temperature Adjustment Place this lava rock material on burner tilesFlame Characteristics Flame adjustment knob for SIT valveBurner and Burner Compartment Cleaning Standing Pilot Control SystemCleaning Electronic Ignition System Brass Trim360DVS Series 360DVSL 360DVSR 360DVS Series Direct Vent Fireplaces Product Covered by this Warranty If Warranty Service is NEEDED…Efficiency Ratings AFUE%

360DVS3, 360DVSL, 360DVSR, 360DVS2 specifications

Vermont Casting offers a range of high-quality gas stoves designed to enhance home heating and add aesthetic appeal. Among their most popular models are the 360DVSR, 360DVSL, 360DVS2, and 360DVS3. Each of these models features unique characteristics and innovative technologies that set them apart in the world of home heating.

The 360DVSR is a versatile choice known for its superb efficiency and heating capabilities. This model employs advanced technology to ensure optimal performance, featuring a heat exchanger that maximizes heat transfer while minimizing fuel consumption. The DVSR boasts a stunning design with a wide viewing area, allowing users to enjoy the mesmerizing flames. Its easy-to-use electronic ignition ensures that lighting the stove is hassle-free, and it also comes with remote control options for added convenience.

The 360DVSL, on the other hand, is tailored for those seeking a more contemporary aesthetic. This model offers the same outstanding energy efficiency as the DVSR but incorporates a sleek, low-profile design that fits seamlessly with modern interiors. Its programmable thermostat allows users to maintain their desired temperature easily, while the dual-fuel capability enables the use of either natural gas or propane. The 360DVSL is perfect for families looking to combine style with function.

For larger spaces, the 360DVS2 and 360DVS3 are optimal choices. These models are designed with a greater heating capacity, making them suitable for larger rooms or open-concept living spaces. The 360DVS2 features a dual burner system that allows for variable heat output, improving comfort in varying conditions. It also includes a realistic log set that adds to the ambiance of the flame.

Meanwhile, the 360DVS3 distinguishes itself with a three-sided design, offering a panoramic view of the fire from multiple angles. This makes it a stunning focal point in any room. Each model is built with durable materials and features Vermont Casting’s renowned craftsmanship, ensuring longevity and reliability.

In summary, Vermont Casting's range of 360DVSR, 360DVSL, 360DVS2, and 360DVS3 gas stoves combine advanced technology, efficiency, and timeless design. Whether you are looking for versatility, contemporary style, or higher heating capacity, these models offer a solution to meet varied needs while enhancing any living space with the warm ambiance of a gas fire.