Millivolt models come standard with the manually-modulated gas valve; flame ap- pearance and heat output can be con- trolled at the gas valve.

Input of millivolt models is shown in the following table:

Millivolt Models with

Manually-Modulated Gas Valve

Natural Gas

Propane Gas

D, DT,

Input rate

D, DT,

Input rate

DR

DR

(BTU/H)

(BTU/H)

Series

Series

 

 

500

17,500 to

500

17,500 to

23,000

23,000

 

 

600

21,500 to

600

22,500 to

29,000

29,000

 

 

800

24,000 to

800

25,500 to

32,000

32,000

 

 

Electronic Models -

Electronic models have a fixed rate gas valve. Input of electronic models is shown in the following table:

Electronic Models with Fixed-Rate Gas Valve

Natural and Propane Gas

D, DT, DR Series

Input rate (BTU/H)

500

23,000

600

29,000

800

32,000

All Models -

Maximum manifold pressure is 3.5 in. w.c. (0.87 kPa) for natural gas and 10 in. w.c. (2.49 kPa) for LP/Propane gas.

Installations at Altitudes of 0 to 4500 ft.- Units are tested and approved for elevations of 0 to 4500 feet (0 to 1372 meters).

Installations at Altitudes above 4500 ft.- For elevations above 4500 feet (1372 meters), install the unit according to the regulations of the local authorities having jurisdiction and, in the USA, the latest edition of the National Fuel Gas Code (ANSI Z223.1) or, in Canada, the latest edition of the CAN1-B149.1 and .2 codes.

Table 1 shows the units' gas orifice size for the elevations indicated.

D, DT,

Orifice size

Elevation

DR

 

 

Feet

Series

Nat.

Prop.

(meters)

 

 

 

 

 

 

500

0.090 in.

#54

 

 

 

 

0-4500

600

#36

#52

(0-1370)

 

 

 

800

#33

0.065 in.

 

 

 

 

 

Table 1

The millivolt appliances are manually controlled and feature a spark ignitor (piezo) that allows the appliance's pilot gas to be lit without the use of matches or batteries. This system provides continued service in the event of a power outage.

Do not use these appliances if any part has been under water. Immediately call a quali- fied, professional service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water.

Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifié pour inspecter l'appareil et remplacer toute partie du système de contrôle et toute commande qui ont été plongés dans l'eau.

This appliance may be installed in an af- termarket permanently located, manufac- tured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This ap- pliance is not convertible for use with other gases, unless a certified kit is used.

Cet appareil peut être installé dans un maison préfabriquée (É.-U. seulement) ou mobile déjà installée à demeure si les réglements locaux le permettent.

Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique. Ne pas l'utiliser avec d'autres gaz sauf si un kit de conversion certifié est installé.

Test gage connections are provided on the front of the millivolt gas control valve (iden- tified IN for the inlet and OUT for the mani- fold side). A ¹⁄₈" NPT test gage connection is provided at the inlet and outlet side of the electronic gas control valve.

Minimum inlet gas pressure to these appliances is 5.0 inches water column (1.24 kPa) for natural gas and 11 inches water column (2.74 kPa) for propane for the purpose of input adjustment.

Maximum inlet gas supply pressure to these appliances is 10.5 inches water column (2.61 kPa) for natural gas and 13.0 inches water column (3.23 kPa) for propane.

These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure test- ing of the gas supply piping system at test pressures equal to or less than ¹⁄₂ psig (3.5 kPa).

These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure test- ing of that system at pressures in excess of ¹⁄₂ psig (3.5 kPa).

These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nau- sea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a qualified professional, as it may not be operating correctly.

WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING IN- STRUCTIONS PROVIDED IN THIS DOCU- MENT WILL RESULT IN AN IMPROP- ERLY INSTALLED AND OPERATING AP- PLIANCE, VOIDING ITS WARRANTY. ANY CHANGE TO THIS APPLIANCE AND/OR ITS OPERATING CONTROLS IS DANGER- OUS. IMPROPER INSTALLATION OR USE OF THIS APPLIANCE CAN CAUSE SERI- OUS INJURY OR DEATH FROM FIRE, BURNS, EXPLOSION OR CARBON MON- OXIDE POISONING.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES. USE CAUTION AROUND THE APPLIANCE TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CARE- FULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIALS ON OR NEAR THIS APPLIANCE.

AVERTISSEMENT: SURVEILLER LES ENFANTS. GARDER LES VÊTEMENTS, LES MEUBLES, L'ESSENCE OU AUTRES LIQUIDES À VAPEUR INFLAMMABLES

ÀCOTE DE L'APPAREIL.

LOCATION

In selecting the location, the aesthetic and func- tional use of the appliance are primary concerns. However, vent system routing to the exterior and access to the fuel supply are also important. Consideration should be given to traffic ways, furniture, draperies, etc., due to elevated surface temperatures (see Figure 2 ).

3

Image 3
Contents DT-600CEN DR-800CEP Retain These Instructions For Future ReferenceDT-500CEN DR-600CEP DR-500CEP DT-800CENTable of Contents All Models Cote DE Lappareil LocationMillivolt Models Electronic ModelsModel No Shelf Height inches mm Typical LocationsAppliance and Vent Clearances Area above it. See .Typical Installation Sequence Detailed Installation StepsVent Termination Clearances Exterior Horizontal Vent Termination Clearance Requirements DR-600mm 1019 1554 Fireplace Framing SpecificationsFraming Dimensions DR-800Fireplace Specifications Fireplace Framing SpecificationsFor D-500, DT-500 and DR- 500 Models only Combined TOP and Rear Vent Units Install the Vent SystemVertical Straight Installation Vent / Appliance Collar Connection Vertical Offset Installation10¹⁄₂ 17 ³⁄₄ 267 mm 451 mm Framing Dimensions for Roof Pitch12/12 10¹⁄₂ 267 mm 305 mmMaximum Table aVertical Vent FIGURES/TABLES Table B+ H 1 = 20 feet 6.2 m Max Table EMinimum +H 1 MaximumPlan the vent run Typical Horizontal Vent InstallationInstall firestop/spacer at ceiling Horizontal Outside Wall Termination SystemSV4.5HTR Install Firestop/Spacer at exterior wallInstall the desired termination ¹⁄₄ 32 mm as shown in FigureElbow Connection AT Appliance Table FTable G Horizontal Vent FIGURES/TABLESTable J SF4.5HFSF4.5BF 610 914 +H 1+H+H+H 1+H 2 = 40 feet 12.4 m Max +H 1+H 2= 20 feet 6.2 m MaxInstall the Outer Flex Pipe Route Flex VentAttach Adapter to Appliance Collar, or Secure Vent Sections Electronic Wiring See or Field WiringWiring Optional Forced AIR Blower KIT SIT and Honeywell Millivolt WiringConnecting GAS Line Wall Details Burner AdjustmentsHood Installation Finishing RequirementsCold Climate Insulation Installation Accessories GAS Conversion Kits .2 Installation CodeMillivolt Appliances SIT Systems Pilot for SIT Millivolt Gas ValveSide Of The Hex Fitting LHP

600 specifications

TOA Electronics, a leading manufacturer in the audio and communication equipment industry, has built a reputation for delivering high-quality products designed for commercial and professional applications. One of their standout offerings is the TOA 600 series of amplifiers, which combines power, clarity, and reliability, catering to a diverse range of sound reinforcement needs.

The TOA 600 series amplifiers are engineered with a wide power range, accommodating various installations from small venues to large auditoriums. This versatility is complemented by advanced technologies that enhance audio performance. The amplifiers boast a compact design, making them easy to integrate into existing sound systems without occupying excessive space.

One of the key features of the TOA 600 series is its high efficiency. Utilizing Class D amplification technology, these amplifiers deliver clear and powerful audio while consuming less energy than traditional analog amplifiers. This not only reduces operational costs but also minimizes heat generation, enhancing the long-term reliability of the equipment.

Another notable characteristic of the TOA 600 series is its built-in digital signal processing (DSP) capabilities. This technology allows users to optimize sound quality in real-time by adjusting parameters such as equalization, compression, and limiting. Users can create tailored sound profiles that suit specific environments or applications, ensuring optimal audio clarity and consistency.

The TOA 600 series also includes extensive protection circuits that safeguard the amplifier against common faults like overcurrent, overload, and overheating. This ensures durability and serviceability, making it a preferred choice for professionals who require dependable audio solutions.

Additionally, the amplifiers support multiple input options, including balanced XLR inputs and unbalanced RCA connectors, allowing for seamless integration with a variety of audio sources such as microphones, mixers, and playback devices. The built-in network capability also facilitates remote control and monitoring, providing users with greater flexibility and convenience.

Overall, the TOA 600 series amplifiers are a testament to TOA Electronics' commitment to quality and innovation in the audio industry. With their advanced features, robust construction, and user-friendly interface, these amplifiers are ideal for anyone seeking reliable and high-performance audio solutions for commercial or professional applications. Whether in schools, venues, or corporate environments, the TOA 600 series amplifiers deliver unparalleled sound quality and reliability.