TOA Electronics 600 Fireplace Specifications, Fireplace Framing Specifications

Page 8

8

FIREPLACE FRAMING SPECIFICATIONS

 

 

 

 

*These dimensions occur when one 45

 

b

 

degree elbow is connected directly to the

 

 

 

 

 

 

appliance collar.

 

 

Note-

 

 

*6¹⁄₈

 

Venting requirements for rear vent applications in corner

(156)

8³⁄₁₆ (208)

installations for D-500, DT-500 AND DR-500 models only -

 

- the round termination (SV4.5HTR) may not be used

 

 

- the horizontal vent length “a” to “b,” must not exceed 28

 

 

inches (711 mm)

 

 

 

 

 

 

40⁵⁄₈

 

28³⁄₄

 

 

(1032)

 

 

 

 

(730)

 

 

 

 

 

 

 

a

*19³⁄₁₆

 

 

 

(487)

Back wall of chase/enclosure

 

 

 

(including any finishing materials)

 

 

 

 

 

 

35¹⁄₈

 

 

 

 

(892)

 

 

Inches

 

57¹⁄₂

 

 

(millimeters)

 

(1461)

 

 

CORNER FRAMING WITH SMALL SQUARE HORIZONTAL TERMINATION(SV4.5HTSS)

Figure 11

 

 

FOR D-500, DT-500 AND DR- 500 MODELS ONLY)

FIREPLACE SPECIFICATIONS

 

 

 

FRAMING

G

(Louvered Front Model Shown)

 

 

SPACERS

H

*CONCENTRIC FLUE

 

 

(Top and Sides

 

 

and Rear)

 

FLUE - 4¹⁄₂ (114)

 

 

 

COMBUSTION AIR - 7¹⁄₂ (190)

 

 

 

 

* D models have a top and rear vent DR models have only a rear vent

9DT models have only a top vent

(229)

Top View

NOTE - Hood shown as

 

 

 

 

positioned in louvered

 

3 (76)

front model.

¹⁄₂ (13)

E

 

 

16

 

GAS INLET

(406)

 

 

 

(Either Side

 

 

and bottom)

 

 

 

OPTIONAL ELECTRICAL

5¹⁄₂

 

 

 

INLET KNOCKOUT

(140)

 

A

 

REQUIRING A FIELD

 

 

 

PROVIDED JUNCTION

9³⁄₈

 

C

B

BOX (Either Side)

(238)

F**

D

 

 

2

 

 

3 (76)

 

 

 

(53)

ELECTRICAL INLET

 

 

1³⁄₈

 

 

 

(35)

 

2³⁄₄ x 2 (70 x 51) COVER

 

 

 

 

PLATE with KNOCKOUT)

 

 

Front View

 

 

 

 

 

Right Side View

**Rear vent models only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

A

B

C

D

E

 

**F

G

 

H

 

 

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D-500

in.

35 1/8

32 1/8

19

29 1/2

35 1/8

21 11/16

24 7/8

 

12 7/16

 

 

DT-500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

892

816

483

749

892

551

632

 

316

 

 

DR-500

 

 

 

D-600

in.

40 1/8

37 1/8

24

34 1/2

40 1/8

26 11/16

29 7/8

14 15/16

 

 

DT-600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

1019

943

610

876

1019

678

759

 

379

 

 

DR-600

 

 

 

D-800

in.

40 1/8

37 1/8

24

39 1/2

45 1/8

26 11/16

34 7/8

 

17 7/16

 

 

DT-800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**Rear Vent Units Only.

 

mm

1146

943

610

1003

1146

678

886

 

443

Figure 12

DR-800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

 

 

 

 

Image 8
Contents Retain These Instructions For Future Reference DT-500CEN DR-600CEPDR-500CEP DT-800CEN DT-600CEN DR-800CEPTable of Contents Cote DE Lappareil Location Millivolt ModelsElectronic Models All ModelsTypical Locations Appliance and Vent ClearancesArea above it. See . Model No Shelf Height inches mmVent Termination Clearances Typical Installation SequenceDetailed Installation Steps Exterior Horizontal Vent Termination Clearance Requirements Fireplace Framing Specifications Framing DimensionsDR-800 DR-600mm 1019 1554For D-500, DT-500 and DR- 500 Models only Fireplace SpecificationsFireplace Framing Specifications Install the Vent System Combined TOP and Rear Vent UnitsVertical Straight Installation Vertical Offset Installation Vent / Appliance Collar ConnectionFraming Dimensions for Roof Pitch 12/1210¹⁄₂ 267 mm 305 mm 10¹⁄₂ 17 ³⁄₄ 267 mm 451 mmTable a Vertical Vent FIGURES/TABLESTable B MaximumTable E Minimum+H 1 Maximum + H 1 = 20 feet 6.2 m MaxTypical Horizontal Vent Installation Install firestop/spacer at ceilingHorizontal Outside Wall Termination System Plan the vent runInstall Firestop/Spacer at exterior wall Install the desired termination¹⁄₄ 32 mm as shown in Figure SV4.5HTRTable F Table GHorizontal Vent FIGURES/TABLES Elbow Connection AT ApplianceSF4.5BF Table JSF4.5HF +H 1+H +H+H 1+H 2 = 40 feet 12.4 m Max+H 1+H 2= 20 feet 6.2 m Max 610 914Attach Adapter to Appliance Collar, or Secure Vent Sections Install the Outer Flex PipeRoute Flex Vent Field Wiring Wiring Optional Forced AIR Blower KITSIT and Honeywell Millivolt Wiring Electronic Wiring See orConnecting GAS Line Burner Adjustments Hood InstallationFinishing Requirements Wall DetailsCold Climate Insulation Installation Accessories .2 Installation Code GAS Conversion KitsSide Of The Hex Fitting Millivolt Appliances SIT SystemsPilot for SIT Millivolt Gas Valve LHP

600 specifications

TOA Electronics, a leading manufacturer in the audio and communication equipment industry, has built a reputation for delivering high-quality products designed for commercial and professional applications. One of their standout offerings is the TOA 600 series of amplifiers, which combines power, clarity, and reliability, catering to a diverse range of sound reinforcement needs.

The TOA 600 series amplifiers are engineered with a wide power range, accommodating various installations from small venues to large auditoriums. This versatility is complemented by advanced technologies that enhance audio performance. The amplifiers boast a compact design, making them easy to integrate into existing sound systems without occupying excessive space.

One of the key features of the TOA 600 series is its high efficiency. Utilizing Class D amplification technology, these amplifiers deliver clear and powerful audio while consuming less energy than traditional analog amplifiers. This not only reduces operational costs but also minimizes heat generation, enhancing the long-term reliability of the equipment.

Another notable characteristic of the TOA 600 series is its built-in digital signal processing (DSP) capabilities. This technology allows users to optimize sound quality in real-time by adjusting parameters such as equalization, compression, and limiting. Users can create tailored sound profiles that suit specific environments or applications, ensuring optimal audio clarity and consistency.

The TOA 600 series also includes extensive protection circuits that safeguard the amplifier against common faults like overcurrent, overload, and overheating. This ensures durability and serviceability, making it a preferred choice for professionals who require dependable audio solutions.

Additionally, the amplifiers support multiple input options, including balanced XLR inputs and unbalanced RCA connectors, allowing for seamless integration with a variety of audio sources such as microphones, mixers, and playback devices. The built-in network capability also facilitates remote control and monitoring, providing users with greater flexibility and convenience.

Overall, the TOA 600 series amplifiers are a testament to TOA Electronics' commitment to quality and innovation in the audio industry. With their advanced features, robust construction, and user-friendly interface, these amplifiers are ideal for anyone seeking reliable and high-performance audio solutions for commercial or professional applications. Whether in schools, venues, or corporate environments, the TOA 600 series amplifiers deliver unparalleled sound quality and reliability.