TOA Electronics 600 installation instructions Table of Contents

Page 2

2

TABLE OF CONTENTS

 

 

Packaging

page

2

Introduction

page

2

General Information

page

2

Location

..........................................

page

3

Appliance and Vent Clearances

page

4

Vent Termination Clearances

page

5

Typical Installation Sequence

page

5

Detailed Installation Steps

page

5

Step 1.

Framing

page

5

Step 2. Routing Gas Line

page

5

Fireplace Specifications

page

8

Step 3. Install the Vent System

page

9

Vertical Termination Systems

page

10

Vent Section Length Chart

page

10

Vertical Vent Tables and Figures

page

13

Horizontal Termination System

page

15

Horizontal Vent Tables and Figures . page

17

Venting Using Flexible Vent Pipe

page

20

Step 4.

Field Wiring

page

21

Step 5. Optional Blower Kit Wiring

page

21

Step 6. Connecting Gas Line

page

22

Step 7.

Installing Logs

page

22

Step 8.

Checking Unit Operation

page

22

Step 9. Installing Glass Door

page

23

Step 10. Burner Adjustments

page

23

Step 11. Hood Installation

page

23

Finishing Requirements

page

23

Cold Climate Insulation

page

24

Installation Accessories

page

25

Gas Conversion Kits

page 26

This installation manual will help you obtain a safe, efficient, dependable installation for your appliance and vent system.

Please read and understand these instructions before beginning your installation.

PACKAGING

The assembled vented gas fireplace heater is packaged with:

1 - one log set located in firebox area.

2 - one envelope containing the literature package which consists of the homeowner's manual, installation instructions, log set supplement and warranty; envelope is lo- cated in the control area.

3- one vent restrictor to be applied as shown on page 9; restrictor is taped to the envelope.

4 - one hood located behind the top panel.

5 - one bag of decorative volcanic stone lo- cated in the control area.

6 - one bag of glowing embers located in the control area.

INTRODUCTION

These vented gas fireplace heaters are sealed combustion, air circulating gas fireplaces de- signed for residential applications. These ap- pliances must be installed with the Secure Vent™ and /or Secure Flex™ vent systems routed to the outside atmosphere.

Millivolt appliances are designed to operate on natural or propane gas. A millivolt gas control valve with piezo ignition system provides safe, efficient operation. External electrical power is required to operate the optional blower if in- stalled in these units.

Electronic appliances are designed to operate on natural or propane gas. An electronic inter- mittent pilot ignition system provides safe, efficient operation. External electrical power is required to operate these units.

These appliances comply with National Safety Standards and are tested and listed by Omni- Test Laboratories (Report No. 116-F-13-4) to ANSI Z21.88-2002 (in Canada, CSA-2.33-2002), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplace heaters.

Both millivolt and electronic versions of these appliances are listed by Omni-Test Laboratories for installation in bedrooms and mobile homes.

Installation must conform to local codes. In the absence of local codes, installation must com- ply with the current National Fuel Gas Code, ANSI Z223.1. (In Canada, the current CAN-1 B149 installation code.) Electrical wiring must comply with the National Electrical Code ANSI/ NFPA 70 - (latest edition). (In Canada, the current CSA C22-1 Canadian Electrical Code.)

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.

GENERAL INFORMATION

Note: Installation and repair should be per- formed by a qualified service person. The appli- ance should be inspected annually by a quali- fied professional service technician. More fre- quent inspections and cleanings may be re- quired due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean.

S'assurer que le brùleur et le compartiment des commandes sont propres. Voir les in- structions d'installation et d'utilisation qui accompagnent l'appareil.

Provide adequate clearances around air open- ings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.

These appliances are designed to operate on natural or propane gas only.

TYPICAL INSTALLATION

Figure 1

Image 2
Contents DR-500CEP DT-800CEN Retain These Instructions For Future ReferenceDT-500CEN DR-600CEP DT-600CEN DR-800CEPTable of Contents Electronic Models Cote DE Lappareil LocationMillivolt Models All ModelsArea above it. See . Typical LocationsAppliance and Vent Clearances Model No Shelf Height inches mmVent Termination Clearances Typical Installation SequenceDetailed Installation Steps Exterior Horizontal Vent Termination Clearance Requirements DR-800 Fireplace Framing SpecificationsFraming Dimensions DR-600mm 1019 1554For D-500, DT-500 and DR- 500 Models only Fireplace SpecificationsFireplace Framing Specifications Install the Vent System Combined TOP and Rear Vent UnitsVertical Straight Installation Vertical Offset Installation Vent / Appliance Collar Connection10¹⁄₂ 267 mm 305 mm Framing Dimensions for Roof Pitch12/12 10¹⁄₂ 17 ³⁄₄ 267 mm 451 mmTable B Table aVertical Vent FIGURES/TABLES Maximum+H 1 Maximum Table EMinimum + H 1 = 20 feet 6.2 m MaxHorizontal Outside Wall Termination System Typical Horizontal Vent InstallationInstall firestop/spacer at ceiling Plan the vent run¹⁄₄ 32 mm as shown in Figure Install Firestop/Spacer at exterior wallInstall the desired termination SV4.5HTRHorizontal Vent FIGURES/TABLES Table FTable G Elbow Connection AT ApplianceSF4.5BF Table JSF4.5HF +H 1+H 2= 20 feet 6.2 m Max +H 1+H+H+H 1+H 2 = 40 feet 12.4 m Max 610 914Attach Adapter to Appliance Collar, or Secure Vent Sections Install the Outer Flex PipeRoute Flex Vent SIT and Honeywell Millivolt Wiring Field WiringWiring Optional Forced AIR Blower KIT Electronic Wiring See orConnecting GAS Line Finishing Requirements Burner AdjustmentsHood Installation Wall DetailsCold Climate Insulation Installation Accessories .2 Installation Code GAS Conversion KitsSide Of The Hex Fitting Millivolt Appliances SIT SystemsPilot for SIT Millivolt Gas Valve LHP

600 specifications

TOA Electronics, a leading manufacturer in the audio and communication equipment industry, has built a reputation for delivering high-quality products designed for commercial and professional applications. One of their standout offerings is the TOA 600 series of amplifiers, which combines power, clarity, and reliability, catering to a diverse range of sound reinforcement needs.

The TOA 600 series amplifiers are engineered with a wide power range, accommodating various installations from small venues to large auditoriums. This versatility is complemented by advanced technologies that enhance audio performance. The amplifiers boast a compact design, making them easy to integrate into existing sound systems without occupying excessive space.

One of the key features of the TOA 600 series is its high efficiency. Utilizing Class D amplification technology, these amplifiers deliver clear and powerful audio while consuming less energy than traditional analog amplifiers. This not only reduces operational costs but also minimizes heat generation, enhancing the long-term reliability of the equipment.

Another notable characteristic of the TOA 600 series is its built-in digital signal processing (DSP) capabilities. This technology allows users to optimize sound quality in real-time by adjusting parameters such as equalization, compression, and limiting. Users can create tailored sound profiles that suit specific environments or applications, ensuring optimal audio clarity and consistency.

The TOA 600 series also includes extensive protection circuits that safeguard the amplifier against common faults like overcurrent, overload, and overheating. This ensures durability and serviceability, making it a preferred choice for professionals who require dependable audio solutions.

Additionally, the amplifiers support multiple input options, including balanced XLR inputs and unbalanced RCA connectors, allowing for seamless integration with a variety of audio sources such as microphones, mixers, and playback devices. The built-in network capability also facilitates remote control and monitoring, providing users with greater flexibility and convenience.

Overall, the TOA 600 series amplifiers are a testament to TOA Electronics' commitment to quality and innovation in the audio industry. With their advanced features, robust construction, and user-friendly interface, these amplifiers are ideal for anyone seeking reliable and high-performance audio solutions for commercial or professional applications. Whether in schools, venues, or corporate environments, the TOA 600 series amplifiers deliver unparalleled sound quality and reliability.