Important safety requirements
This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition).
Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Part 2 and B.S. 6891 Current Editions.
The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air is required.
However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3.
If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements.
INSTALLATION GUIDANCE INSTRUCTIONS
CLEARANCES REQUIRED
WHEN FITTING THE GAS HOB
WITHOUT A COOKER HOOD ABOVE
700 mm |
|
|
| |
| 400 mm |
|
| |
|
|
| mm |
|
| 50 |
| 55 |
|
| mm |
| 400 mm | |
|
|
| ||
|
|
|
| |
100 | mm |
|
|
|
|
|
|
| |
|
|
| 50 | mm |
|
|
|
|
FO 2027
Location
The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room.
Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm. between the edge of the hob and the wall.
The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 420 mm. If it is fitted below 420 mm. a space of 50
mm.must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm.
A minimum distance of 100 mm. must be left between the side edges of the hob and any adjacent cabinets or walls.
Important
If a 60 cm cooker hood is be installed above the hob, ensure a minimum distance of 780 mm is left between the hanging furniture units beside the cooker hood (see diagram below).
INSTALLATION GUIDANCE INSTRUCTIONS | ||||
|
| CLEARANCES REQUIRED |
| |
| WHEN FITTING THE GAS HOB |
| ||
| WITH A COOKER HOOD ABOVE |
| ||
|
| 600 mm |
|
|
|
| 780 mm min. |
|
|
650 mm |
|
|
| |
| 400 mm |
|
| |
|
| mm |
|
|
| 50 | 55 |
|
|
| mm |
| 400 mm | |
|
|
| ||
100 | mm |
|
|
|
|
|
|
| |
|
| 50 | mm |
|
|
|
|
| |
FO 2231 |
|
|
|
11