Zanussi ZGF 782 manual Instructions for the Installer, Engineer technical data, Overall Dimensions

Page 9

Instructions for the Installer

Engineer technical data

OVERALL DIMENSIONS

Width:

680 mm.

Depth:

510 mm.

Height:

72 mm.

Weight:

12 Kg.

CUT OUT DIMENSIONS

Width:

560 mm.

Depth:

480 mm.

Thickness:

30 mm.

Ignition HT Spark

SUPPLY CONNECTIONS

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

Spark Generator Ispra Control's BF 50066 - 240V

0.6 YA T 120

 

Spark Gap

Fixed

 

 

 

 

 

Rear Left Burner (semi rapid)

Rear Right Burner (semi rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Heat Input

2.0 kW (6824 BTU/HR)

Front Left Burner (auxiliary)

Front Right Burner (rapid)

Heat Input

1.0 kW (3412 BTU/HR)

Heat Input

3.0 kW (10236 BTU/HR)

Central Burner (Ultra-rapid Double-crown)

Heat Input 3.5 kW (11942 BTU/HR)

OFTYPE

GAS

CHARACTERISTICS

BURNER

 

RAPID

SEMI-RAPID

AUXILIARY

ULTRA-RAPID

 

 

 

 

 

 

 

 

 

(large)

(medium)

(small)

(double-crown)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POSITION

 

MAX

MIN

MAX

MIN

MAX

MIN

MAX

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURALGAS

20mbar

=VALUE37.78 MJ/m3 50.7-WsMJ/ m

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

 

3

POWER

kW

3.0

0.65

2.0

0.45

1.0

0.33

3.5

1.2

 

 

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

 

RATE

m3/h

0.286

0.062

0.190

0.043

0.095

0.031

0.333

0.114

 

 

 

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

136

Adjust.

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GASLPG

mbar30/37-28

MJ/Kg49.92=VALUE

NOMINAL THERMAL

 

 

 

 

 

 

 

 

POWER

kW

2.8

0.65

2.0

0.45

1.0

0.33

3.5

1.2

 

 

 

 

 

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

 

RATE

g/h

202

47

144

32

72

24

252

86

 

 

 

NOZZLE REFERENCE

86

40

71

32

50

28

93

56

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

Tap colour

APPLIANCE CLASS : 3

 

 

1/100 mm

 

APPLIANCE

 

 

 

 

 

 

Auxiliary

28

Green

CATEGORY: II2H3+

Semi-rapid

32

Green/Blue

APPLIANCE

Rapid

40

Green/Black

GAS SUPPLY: Natural gas G20 / 20mbar

Ultra-rapid

56

Black/Red

 

Aeration adjustment none

 

 

 

 

 

 

10

Image 9
Contents GAS HOB Model ZGF Child Safety Important Safety InformationService During UseContents Installation When the HOB is First Installed Description of the HobHob Top Operation Using the Wok StandHOB Burners Burner Minimum MaximumHobTop Maintenance and CleaningPan Supports and Wok Stand BurnersSymptom Solution Service and Spare PartsSomething Not Working? Customer CareExclusions This guarantee does not cover Zanussi Guarantee ConditionsEuropean Guarantee Peace of Mind for 24 MonthsEngineer technical data Instructions for the InstallerOverall Dimensions CUT OUT DimensionsLocation Important safety requirementsDimensions are given in mm InstallationGas Connection Cut Out SizeFitting the Hob into the worktop BuildingThis HOB Must be Earthed Electrical connectionsIgnitor Switch Ignitor Unit Wiring DiagramFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Procedure Pressure TestingCommissioning Servicing To Adjust the GAS Rate