Desa SDVBPD, SDVBND Connecting STOVE/BURNER System to GAS Supply, Checking GAS Connections

Page 21

STOVE AND DIRECT-VENT BURNER SYSTEM INSTALLATION

Installing Gas Piping to Stove/Burner System Location (Cont.) Connecting Stove/Burner System to Gas Supply Checking Gas Connections

21

STOVE AND DIRECT-VENT BURNER SYSTEM INSTALLATION

Continued

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged burner system valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 40, page 20. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly.

CONNECTING STOVE/BURNER SYSTEM TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

sealant (resistant to propane/LP gas, not provided)

1.Open lower door panel.

2.Route flexible gas line (provided by installer, see Figure 41) from equipment shutoff valve to burner system. Route flex- ible gas supply line and attach to valve.

3.Check all gas connections for leaks. See Checking Gas Connections, column 2.

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply noncorrosive leak detection solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (con- trol valve) and equipment shutoff valve from gas supply pip- ing systems. Pressures in excess of 1/2 psig (3.5 kPa) will dam- age burner system gas regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas burner system or opening main gas valve located on or near gas meter for natural gas burner system, or using compressed air.

4.Check all joints of gas supply piping system. Apply noncorro- sive leak detection solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Reconnect burner system and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

To Flare Fitting on

Control Valve

Flexible Gas Line from

Equipment Shutoff Valve

Provided by Installer

Figure 41 - Flexible Gas Line

Equipment Shutoff Valve

Natural - To

Gas Supply

Propane/LP -

To External

Regulator

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 42).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas burner system or opening main gas valve located on or near gas meter for natural gas burner system, or using compressed air.

OpenON

POSITION

Equipment

Shutoff

Valve

Closed

Figure 42 - Equipment Shutoff Valve

For morevisit www..com

112126-01B

Image 21
Contents For Your Safety OWNER’S Operation and Installation ManualFor Your Safety What to do if YOU Smell GAS VH series StoveSafety Information Table of ContentsWith stove Product IdentificationPRE-INSTALLATION Preparation Product Features Local CodesGlossary of Terms PRE-INSTALLATION Preparation Cast Iron Stove and DIRECT-VENT Burner System AssemblyStove Body Assembly Locating Threaded Holes for Legs and Door Attachment Removing Front Surround Panel Installing DIRECT-VENT Burner System Into Stove BodyRemoving Screen Optional Amity ModelsTOP View Installing Optional Blower Accessory Installing the BlowerBlower Wiring Layout Thermostat Blower Shown Installing Rear CoverLocation of Vent Termination General VentingGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a Chase Installation for Horizontal TerminationVent Opening Requirements Horizontal Venting Horizontal Termination ConfigurationsVenting with Three 90 Elbows Venting with Two 90 ElbowsFlat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Vertical Termination ConfigurationsVenting with Two 90 Elbow Venting with Two Elbows Vertical Venting Configuration Using Two 90ElbowsParts Lists for Venting Kits and Components High Altitude InstallationVertical Venting Number DescriptionInstalling GAS Piping to STOVE/ Burner System Location Stove and DIRECT-VENT Burner System InstallationInstallation Items Needed Check GAS TypeConnecting STOVE/BURNER System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Pressure Testing Burner System Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Remote Receiver and 9-volt Alkaline Battery Installing Optional Wall Mounted Thermostat GWMT1REMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling Log No Installing Log No Installing LOGS, Lava Rock and Glowing EmbersOperating Stove with Burner System For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceOptional HAND-HELD Remote Operation Manual LightingON/OFF Series Models Ghrcb and Cghrcb Thermostat Series Models Ghrctb and CghrctbPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause Remedy TroubleshootingOrifice Above Gas leak. See Warning statementWiring Diagram SpecificationsReplacement Parts Parts Under WarrantyModels Sdvbnd Sdvbpd Illustrated Parts BreakdownModels SDVBND, Sdvbpd Parts ListVictor Hearth Stove Body Indicates Color Suffix Designation Oxford Amity Stove BodyDescription QTY Indicates Color Suffix DesignationTechnical Service Service HintsAccessories Owners Registration Form For Com 112126-01B Warranty Information
Related manuals
Manual 42 pages 10.67 Kb

SDVBPD, SDVBND specifications

Desa SDVBPD and SDVBND are pioneering advancements in the domain of digital communication, designed to optimize services, enhance user engagement, and streamline processes in various sectors, including education, healthcare, and local governance. These systems have emerged as essential tools for efficient information dissemination and resource management.

One of the main features of Desa SDVBPD is its focus on decentralized communication. By utilizing local infrastructure, this system empowers communities to share information effectively and enhance interactions among residents. It enables local authorities to communicate directly with citizens, ensuring that pertinent information reaches the intended audience promptly. This feature is especially vital in emergency situations, where timely updates can significantly impact community safety and preparedness.

Similarly, SDVBND offers a robust platform for managing digital transactions and records. Its integration of blockchain technology ensures that all data processed is secure, immutable, and transparent. This characteristic is particularly beneficial for local government operations, as it minimizes the risk of fraud and enhances accountability in public service delivery. By leveraging this technology, Desa SDVBND can facilitate smooth and fast transactions between citizens and government entities, thereby transforming the way public services are accessed.

Another remarkable aspect of both systems is their accessibility. Designed with user-friendly interfaces, these platforms cater to individuals of varying technological proficiencies. Mobile compatibility allows users to engage with the systems from smartphones and tablets, making it easier to stay informed and involved. Furthermore, the platforms are multilingual, ensuring that communication is inclusive, reaching diverse populations within communities.

Interoperability stands out as a significant characteristic of Desa SDVBPD and SDVBND. Both systems are designed to seamlessly integrate with existing infrastructure and technologies, such as cloud computing and artificial intelligence. This adaptability enhances their functionality, enabling real-time data analysis and improved decision-making.

In conclusion, Desa SDVBPD and SDVBND represent a significant leap forward in community engagement and service delivery. By leveraging decentralized communication, blockchain technology, accessibility, and interoperability, these systems not only improve operational efficiency but also foster a sense of community empowerment. As they continue to evolve, they hold great promise for enabling smarter, more connected communities that can thrive in an increasingly digital world.