Desa SBVBN(D) installation manual Gas leak. See Warning statement, Above

Page 25

TROUBLESHOOTING

25

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating burner system where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner system produces unwanted odors

1. Gas leak. See Warning statement

 

above

1.Locate and correct all leaks (see Check- ing Gas Connections, pages 14 and 15)

Burner system shuts off in use

1.

High or gusting winds

1.

Burner system has been tested for up to

 

 

 

 

40mph winds. However, extreme con-

 

 

 

 

ditions may occur. See Lighting Instruc-

 

 

 

 

tions on page 19

 

2.

Low line pressure

2.

Contact local propane/LP or natural gas

 

 

 

 

company

 

3.

Pilot is partially clogged

3.

Clean pilot (see Cleaning and Mainte-

 

 

 

 

nance, page 22)

 

4.

Glass too loose and air tight gasket leaks

4.

Tighten glass

 

 

in corners after usage

 

 

 

5.

Bad thermopile

5.

Replace faulty component

 

6.

Improper vent cap installation

6.

Check for proper installation and free-

 

 

 

 

dom from debris or blockage

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

above

 

ing Gas Connections, pages 14 and 15)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1. Gas leak. See Warning statement

 

above

1.Locate and correct all leaks (see Check- ing Gas Connections, pages 14 and 15)

Dark residue on logs or inside of burner

1.

Improper log placement

1.

Properly locate logs (see Installing Logs,

system

 

 

 

Lava Rock, and Glowing Embers, page 18)

 

2.

Air holes at burner inlet blocked

2.

Clean out air holes at burner inlets. Pe-

 

 

 

 

riodically repeat as needed

 

3.

Burner flame holes blocked

3.

Remove blockage or replace burner

 

4.

Poor drafting

4.

See Troubleshooting Venting Problems,

 

 

 

 

Down Drafts section, page 12

For morevisit www..com

112127-01A

Image 25 Contents
For Your Safety What to do if YOU Smell GAS For Your SafetySafety Information Table of ContentsTo operating burner system Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocal Codes Stove Body Assembly Cast Iron Stove and B-VENT Burner System AssemblyRemoving Screen Optional Removing Front Surround PanelAmity Models Victor Hearth ModelsInstalling Optional Blower Accessory Installing B-VENT Burner System Into Stove BodySecurely in place before venting pipes are installed Installing Rear CoverInstallation Precautions Venting InstallationVertical Checking Vent CapacityChimneys High Altitude InstallationRelining Systems Cast Iron Stove and B-VENT Burner System Installation Troubleshooting Venting ProblemsFlue GAS Spillage Causes of Spillage and Corrective ActionInstallation Items Needed Installing GAS Piping to Stove LocationPressure Testing Gas Supply Piping System Connecting STOVE/BURNER System to GAS SupplyChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaInstalling Optional Wall Mounted Thermostat GWMT1 Installing Optional Wall Mount Switch GWMS2Pressure Testing Burner System Gas Connections Will occurInstalling Battery in Receiver Installing Remote ReceiverREMOVING/REPLACING Glass Door Installing 9-Volt Battery in Hand-Held Remote Control UnitRemove glass door. See Removing/Replacing Glass Door, Installing LOGS, Lava ROCK, and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Stove with B-VENT Burner System Lighting InstructionsOptional Remote Thermostat Series Operation Operating Stove with Vent Burner SystemON/OFF Series Models Ghrcb and Cghrcb Pilot Assembly Operating Optional Blower Accessory Inspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementTechnical Service Replacement PartsWiring Diagram Service HintsSbvbnd Sbvbpd SpecificationsModels Sbvbnd and Sbvbpd Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListAmity SCIVF* Series PSCIVF* Series Victor Hearth VH* Series Illustrated Parts BREAKDOWN1LIndicates Color Suffix Designation Amity Stove Body Victor Hearth Stove BodyKEY Part Description QTY Indicates Color Suffix DesignationReceiver and HAND-HELD Remote Control KIT Ghrcb and Cghrcb AccessoriesTHERMOSTATICALLY- Controlled Blower KIT CDA3620TB Stove Hearth Base GC10SPAOwners Registration Form Postage Required 112127-01A Warranty Information