Faber Wall Mount Canopy Rangehood For Ductless Installations, For ALL Installations

Page 8

1.LOWER CHIMNEY DUCTLESS

2.LEFT VENT GRID

3.RIGHT VENT GRID

4.DIVERTER EXTENSION HORIZONTAL (2 PIECES)

5.DUCTLESS DIVERTER

6.CHARCOAL FILTER

FIGURE 8

FOR DUCTLESS INSTALLATIONS

Ductless installations require a Ductless Conversion Kit whose components are pictured in FIGURE 8. Do not use the DAMPER (H in FIGURE 1) for ductless installations. The LOWER CHIMNEY COVER (B in FIGURE 1) should be discarded and replaced by a new one with holes (1 in FIGURE 8).

1.As indicated in FIGURE 8, fit the DUCTLESS DIVERTER

(5) over the duct outlet. Fit the 2 DIVERTER EXTENSION HORIZONTAL pieces (4) on either side of the DUCTLESS DIVERTER.

2. Install the CHARCOALFILTER (6) behind the center grease filter opening by inserting and locking into place, as indicated in FIGURE 9.

FIGURE 9

FOR ALL INSTALLATIONS

1.Remove the cover from the Field Wiring Compartment with a phillips screwdriver. Feed the Power Supply Cable through the electrical knockout. Connect the Power Supply Cable to the range- hood cable. Attach the Power Supply Cable grounding lead to the green screw provided. Attach the White lead of the power supply to the White lead of the rangehood with a twist-on type wire con- nector. Attach the Black lead of the power supply to the Black lead of the rangehood with a twist-on type wire connector. Using the 4 holes provided screw the Field Wiring Compartment to the wall as dictated by your Power Supply Cable location (screws not provided). Replace the cover.

2.Install the UPPER CHIMNEYCOVER (CinFIGURE10)by slightly widening the two sides and hooking them behind the CHIMNEY MOUNTING BRACKETS (E). Secure the sides to the CHIMNEY MOUNTING BRACKETS with the 4 CHIMNEY SCREWS (G).

3.Install the LOWER CHIMNEY COVER (B) by slightly widening the two sides of the LOWER CHIMNEY COVER and hooking them between the UPPER CHIMNEY COVER and the wall making sure that it fits snugly. Secure the LOWER CHIMNEY COVER to the CANOPY SECTION (A) with 2 CHIMNEY SCREWS (G).

 

FIGURE 10

 

 

 

FOR DUCTLESS

 

 

 

 

INSTALLATIONS

 

 

Fit the LEFT AND RIGHT

 

 

VENT GRIDS (2 and 3)

 

 

into the LOWER CHIMNEY

 

 

DUCTLESS holes, making

 

 

sure that the directional

 

 

symbols are towards the top

 

 

andfrontofthehoodandthat

 

 

they connect snugly to the

 

FIGURE 11

DIVERTER EXTENSION

 

HORIZONTAL pieces.

 

 

Version 05/08 - Page 8

Image 8
Contents Lisez Bien Cette Fiche Avant Dinstaller LA Hotte StiloVenting Requirements DuctworkElectrical Requirements For residential use onlyUniquement pour usage menager Règlements DévacuationFiche Technique Électrique Plan the Installation Hardware Package Literature PackageCabinet base Vented to the outside8 min Upper Ductless Not vented to the outside10 min 16 1/8 max Upper Chimney Cover Prepare the Wall Install the RangehoodProceed to for ALL Installations on Next Diverter Extension For Ductless InstallationsFor ALL Installations Wiring Diagram USE and Care InformationFaber Warranty & Service Save for Your Records Plan DE L’INSTALLATION Dimensions d’installatioN Avec Conduit Cheminée Plafond HautCouvercle cheminée 36 poDimensions d’installation Sans Conduit Dextension Pour La Cheminée Plafond HautPo min Couvercle cheminée SupérieurePréparation DU MUR Installation DE LA HotteProcéder À Pour Tout LES Installations Installer le Filtre AU Charbon 6 de la Figure Installations Sans ConduitPour Tout LES Installations Utilisation ET Entretien Enregistrez Votre Information Ci-dessous