Faber CRISTAL HC installation instructions Plan the Ductwork, Recirculating Installations

Page 5

TOOLS NEEDED FOR INSTALLATION

• Saber Saw or Jig Saw

• Drill

• 1 1/4" Wood Drill Bit

• Pliers

• Phillips Screwdriver

• Wire Stripper or Utility Knife

• Metal Snips

• Measuring Tape or Ruler

• Level

• Pencil

• Caulking Gun

• Duct Tape

PLAN THE DUCTWORK

The Cristal HC slideout rangehood is designed to offer wide flexibility of installations. The rangehood can be ducted vertically or horizontally through a 6" round vent. The unit can also be installed in a recirculating configuration. The unit comes standard in the top venting position. FIGURES 1 and 2 show vertical and horizontal installations for this unit. FIGURE 3 shows recirculating installation.

The Cristal HC requires 6" round ductwork. To ensure that the blower performs to its highest possible capacity, ductwork should be as short and straight as possilbe.

PARTS SUPPLIED FOR INSTALLATION

• 1 Backdraft Damper

• 1 Vent Grate (for recirculating installations only)

• 3 front trims, white (already installed), black, and brushed aluminum

• 1 Vinyl Trim

• 1 Literature Package

PARTS NEEDED FOR INSTALLATION

• 2 Conduit Connectors

• Power Supply Cable

• 1 Wall or Roof Cap

• All Metal Ductwork

OPTIONAL ACCESSORIES AVAILABLE

• Charcoal Filters

For non-vented installations only, replace charcoal filters as needed part # 6093034

Theductrunshouldnotexceed35feetifductedwith the required minimum of 6" round duct. Calculate the length of the ductwork by adding the equiva- lent feet in FIGURE A for each piece of duct in the system An example is given in FIGURE B.

For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood's exhaust opening as possible.

45˚ Elbow

3.0 feet

90˚ Elbow

5.0 feet

90˚ Flat Elbow

12.0 feet

Wall Cap

0.0 feet

FIGURE A

 

 

 

 

 

9 Feet Straight Duct

9.0 feet

2 - 90˚ Elbows

10.0 feet

Wall Cap

0.0 feet

Total System

19.0 feet

FIGURE B

 

 

 

VERTICAL DUCTING

FIGURE 1

HORIZONTAL

DUCTING

FIGURE 2

For direct rear venting (FIGURE 2), you must change the blower position. Remove the 12 screws that hold the metal housing to the rangehood body. Remove the 4 screws that hold the blower housing to the metal housing. Rotate the blower 90 degrees toward the back and then flip it over 180 degrees. Be sure that the power supply cable is properly positioned. Replace all screws, making sure that they are firmly fastened.

RECIRCULATING INSTALLATIONS

For recirculating installations (FIGURE 3), Charcoal Filters are necessary. Remove all four grease filters and set aside. Attach one charcoal filter to each end of the blower. Each charcoal filter attaches to the black grid on the side of the blower. Rotate the filter clockwise to install and counterclockwise to remove (FIGURE 3A). Replace all four grease filters. Some ductwork must be installed to exhaust the rangehood back into the kitchen, either at the top of the cabinet or at the face of the soffit. A plastic vent grate (FIGURE 3B) supplied with the rangehood can be used to cover the duct opening. This duct work must not terminate into a dead air space.

ceiling

soffit

ceiling

 

 

vent grate

vent grate

 

 

cabinet

cabinet

6” round

6” round

 

duct

 

duct

hood

 

hood

 

FIGURE 3

 

FIGURE 3A

FIGURE 3B

Version 10/05 - Page 5

Image 5
Contents Read and Save These Instructions Lisez Bien Cette Fiche Avant Dinstaller LA HotteElectrical Requirements Venting RequirementsFor residential use only Ducted fans must always be vented to the outdoorsFiche Technique Électrique Règlements DévacuationAvertissement Pour Minimiser LES Risques CORPORELS, Observer LES PrescriptionsFront Trim Options Cristal HC Dimensions CUT-OUTCustom Front Trim Dimensions Plan the Ductwork Recirculating InstallationsVinyl Strip Install the RangehoodPrepare the Cabinet USE and Care Information Warranty & ServiceWiring Diagram / Diagramme DE Filage Options DE LA Bande Frontale Dimensions DE LA Hotte CUT-OUTLES Dimensions DE LA Bande SUR Mesure Préparation DE Larmoire Installation Pour Recirculation DairPlan DU Conduit Installation DE LA Hotte Découper Louverture OÙ LA Hotte Sera Installée FigureUtilisation ET Entretien Garantie ET Service