ATTACH THE SUPPORT
1.Put a thick, protective covering over cooktop,
2.Determine and clearly mark with a pencil on
.t h e c e i l i n g w h e re the rangehood will be installed.
3. Atemplate(LinFIGURE |
|
6) for mounting the support |
|
is supplied in the carton |
|
with the support. Use this | FIGURE 6 |
template to mark holes for |
|
4. Determine and make necessary cuts for the ductwork. The duct opening is shown on the mounting template (L in FIGURE 6). Install ductwork before mounting the support.
5. IfusingtheHighCeiling Chimney Kit, remove the CHIMNEY COVER from the CHIMNEY EXTENSION (A in FIGURE 7). Position the
CHIMNEY EXTENSION over the CHIMNEY SUPPORT (BinFIGURE
7)so that the outside edges and the electrical holes line up. Attach the CHIMNEYEXTENSIONto
theCHIMNEYSUPPORT
using the 4 bolts (C inFIGURE 7 FIGURE7). Tightenbolts
securely.
6.Determine the proper location for the Power Supply Cable as indicated on the template. Use a 1 1/4" Drill Bit to make this hole.
Run the Power Supply Cable. Use caulking to seal around the hole. DO NOT turn on the power until installation is complete! A knockout is provided at the top of the CHIMNEY SUPPORT (D in FIGURE 8).
7.For ducted installations, place the round DAMPER (N in FIGURE 1) into the exhaust opening of the rangehood and press down.
FIGURE 8
8.Attach the CHIMNEY SUPPORT (D in FIGURE 8) to the ceiling. Makesurethatthesupportisfirmlyattachedtotheceiling. Determine
thedesiredlengthofthesupportstructureandadjustthelengthofthe support by removing the four screws(indicatedinFIGURE8)with a flat head screwdriver. Once the length of the support is determined, install and tighten the four screws.
FOR DUCTLESS INSTALLATIONS
Ductless installations require a Ductless Conversion Kit whose components are pictured in FIGURE 9. Do not use the DAMPER (N in FIGURE 1) for ductless installations. The LOWER CHIMNEY COVER (B in FIGURE 1) should be discarded and replaced by the new one with holes from theDuctlessConversionKit (D in FIGURE 9).
As indicated in FIGURE 9, place the DUCTLESS DIVERTER (A) over the exhaust opening of the EASY CUBE (E). FittheDUCTLESS DIVERTER EXTENSIONS HORIZONTAL (B) into the DIVERTER (A).
MAKE THE ELECTRICAL CONNECTION
Remove the cover from the field wiring compartment. DO NOT turn on the power until installation is complete! Connect the Power Supply Cable to the rangehood. Attach the White lead of the power supply to the White lead of the rangehood with a
INSTALLING THE RANGEHOOD
1.The UPPER CHIMNEY COVER (C in FIGURE 10)
attaches using two screws provided (G in FIGURE 10). If using the High Ceiling Chimney Kit, use the
UPPER CHIMNEY COVER supplied with the kit. Slide up and attach the UPPER CHIMNEY COVER.
2. Attach the duct work to the DAMPER (N in FIGURE 1). Make sure to seal all joints with duct tape to prevent leaks.
3. The LOWER CHIMNEY COVER (B in FIGURE 10) attaches using two screws provided (G in FIGURE 10). Install the
LOWER CHIMNEY COVER
by sliding it up over theFIGURE 10 support and the UPPER
CHIMNEY COVER.
For ductless installations, line up the DUCTLESS DIVERTER EXTENSIONS HORIZONTAL (B in FIGURE 9) with the holes in the LOWER CHIMNEY COVER (D in FIGURE 9) and snap in the VENT GRIDS (C in FIGURE 9).