Faber Diamante Isola manual Attach the Support, AtemplateLinFIGURE, For Ductless Installations

Page 7
FIGURE 9

ATTACH THE SUPPORT

1.Put a thick, protective covering over cooktop, set-in range or countertop to protect from damage or dirt.

2.Determine and clearly mark with a pencil on

.t h e c e i l i n g w h e re the rangehood will be installed.

3. Atemplate(LinFIGURE

 

6) for mounting the support

 

is supplied in the carton

 

with the support. Use this

FIGURE 6

template to mark holes for

 

4. Determine and make necessary cuts for the ductwork. The duct opening is shown on the mounting template (L in FIGURE 6). Install ductwork before mounting the support.

5. IfusingtheHighCeiling Chimney Kit, remove the CHIMNEY COVER from the CHIMNEY EXTENSION (A in FIGURE 7). Position the

CHIMNEY EXTENSION over the CHIMNEY SUPPORT (BinFIGURE

7)so that the outside edges and the electrical holes line up. Attach the CHIMNEYEXTENSIONto

theCHIMNEYSUPPORT

using the 4 bolts (C inFIGURE 7 FIGURE7). Tightenbolts

securely.

6.Determine the proper location for the Power Supply Cable as indicated on the template. Use a 1 1/4" Drill Bit to make this hole.

Run the Power Supply Cable. Use caulking to seal around the hole. DO NOT turn on the power until installation is complete! A knockout is provided at the top of the CHIMNEY SUPPORT (D in FIGURE 8).

7.For ducted installations, place the round DAMPER (N in FIGURE 1) into the exhaust opening of the rangehood and press down.

FIGURE 8

8.Attach the CHIMNEY SUPPORT (D in FIGURE 8) to the ceiling. Makesurethatthesupportisfirmlyattachedtotheceiling. Determine

thedesiredlengthofthesupportstructureandadjustthelengthofthe support by removing the four screws(indicatedinFIGURE8)with a flat head screwdriver. Once the length of the support is determined, install and tighten the four screws.

FOR DUCTLESS INSTALLATIONS

Ductless installations require a Ductless Conversion Kit whose components are pictured in FIGURE 9. Do not use the DAMPER (N in FIGURE 1) for ductless installations. The LOWER CHIMNEY COVER (B in FIGURE 1) should be discarded and replaced by the new one with holes from theDuctlessConversionKit (D in FIGURE 9).

As indicated in FIGURE 9, place the DUCTLESS DIVERTER (A) over the exhaust opening of the EASY CUBE (E). FittheDUCTLESS DIVERTER EXTENSIONS HORIZONTAL (B) into the DIVERTER (A).

MAKE THE ELECTRICAL CONNECTION

Remove the cover from the field wiring compartment. DO NOT turn on the power until installation is complete! Connect the Power Supply Cable to the rangehood. Attach the White lead of the power supply to the White lead of the rangehood with a twist-on type wire connector. Attach the Black lead of the power supply to the Black lead of the rangehood with a twist-on type wire connector. Connect the Green (Green and Yellow) ground wire under the Green grounding screw.

INSTALLING THE RANGEHOOD

1.The UPPER CHIMNEY COVER (C in FIGURE 10)

attaches using two screws provided (G in FIGURE 10). If using the High Ceiling Chimney Kit, use the

UPPER CHIMNEY COVER supplied with the kit. Slide up and attach the UPPER CHIMNEY COVER.

2. Attach the duct work to the DAMPER (N in FIGURE 1). Make sure to seal all joints with duct tape to prevent leaks.

3. The LOWER CHIMNEY COVER (B in FIGURE 10) attaches using two screws provided (G in FIGURE 10). Install the

LOWER CHIMNEY COVER

by sliding it up over theFIGURE 10 support and the UPPER

CHIMNEY COVER.

For ductless installations, line up the DUCTLESS DIVERTER EXTENSIONS HORIZONTAL (B in FIGURE 9) with the holes in the LOWER CHIMNEY COVER (D in FIGURE 9) and snap in the VENT GRIDS (C in FIGURE 9).

Version 08/06 - Page 7

Image 7
Contents Read and Save These Instructions Lisez Bien Cette Fiche Avant Dinstaller LA HotteElectrical Requirements Venting RequirementsFor residential use only Uniquement pour usage menager Règlements DévacuationRèglements Dévacuation Additionell Fiche Technique ÉlectriqueOptional Accessories Available Tools Needed for InstallationParts Supplied for Installation Parts Needed for InstallationVented to the outside Plan the Installation15 3/8 max Not vented to the outsideAtemplateLinFIGURE For Ductless InstallationsInstalling the Rangehood Attach the SupportMake the Internal Electrical Connections Install the grease filters using two hands by first pullingUSE and Care Information Warranty & ServiceDéballer LA Hotte Installation DU SupportCalcul DE Longueur DU Conduit Dimensions D’INSTALLATION Avec Conduit Plan DE L’INSTALLATIONTable de cuisson Dimensions D’INSTALLATION Sans ConduitInstallation DU Hotte Installations Sans ConduitBrancher LE Câble Dalimentation Connecter LES Connecteurs Interne De la la Hotte a de la au treillis prévuUtilisation ET Entretien Garantie ET ServiceVersion 08/06