Hunter Fan 81021, 43041-01 manual Preventative Maintenance

Page 2

! W a r n i n g

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer.

2.Before servicing or cleaning the unit, switch power off at ser- vice panel and lock the service disconnecting means to prevent power from being switched on accidentally. when the service disconnecting means cannot be locked, securely fasten a promi- nent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

4.Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufac- turer’s guideline and safety standards,such as those published by the National Fire Prevention Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning

Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

8.Never place a switch where it can be reached from a tub or shower.

9.Install fan at least 5 feet (1.52 m) above the floor.

10.This unit must be grounded.

11.Unit must not be installed in a ceiling thermally insulated to a value greater than R40.

!C A U T I O N

1.For general ventilating use only. Do not use to exhaust haz- ardous or explosive materials and vapors.

2.To avoid motor bearing damage and noisy/unbalanced impel- lers, keep drywall spray, construction dust, etc. off power unit.

3.DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward.

4.Please read specification label on product for further infor- mation and requirements.

!W a r n i n g

DISCONNECT ELECTRIC

POWER SUPPLY

AND LOCK OUT

SERVICE PANEL BEFORE

SERVICING UNIT

PREVENTATIVE MAINTENANCE

A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.

TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders.

TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove

motor plate, find the single tab on the motor plate (located next to the recepta- cle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screw- driver. Gently vacuum fan, motor and interior of housing.

METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.

MAINTENANCE

The motor is permanently lubricated and never needs oiling. If the motor bear- ings are making excessive or unusual

noises, replace the motor with the exact service motor. You should replace the impeller at the same time.

COOKING AREA

 

Do Not Install Above

 

Or Inside This Area

 

45°

45°

 

 

Cooking

Floor

 

 

 

Equipment

 

2

43041-01 01/31/2008

Image 2
Contents Installation I d e Preventative Maintenance For replacements X4 aBefore Installation Choose Installation Option A14 A13A12 New Construction attaching to joistA16 A15A17 A18B12 A21 A22B11 B13 B14B18 B15B16 B17B24 B25 B20 B21B22 C12 Existing Construction accessible from aboveB26 B27 C14 C13C15 C16C21 C19C20 C22C24 C23C25 C26D12 Existing Construction accessible only from belowC29 D13D17 D15D16 D18D22 D19 D20D21 D23Position the strain relief bracket under the motor as shown E11 E10Trouble Shooting Warranty Limited Warranty43041-01 01/31/2008 Í a S t a l a c i ó n Precaución Verifique todos los Antes de la instalación Escoja la opción de instalación Construcción nueva fijación a la viga Soplador Cuelgue DEL Mazo DE Cables A21 Construcción nueva suspendido entre vigasFije los rieles con los tornillos B24 B26 Construcción existente accesible desde arribaC13 C14 C15 C16Apriete los tornillos del aliviador de tensiones Encendido Apagado Vaya al paso En la página 40 para Fijar la rejilla Construcción existente accesible sólo desde abajoD17 D18 D19 To DE Iluminación Cuelgue DEL Mazo DE Cables Enrosque la cubierta ornamental Solución de problemas Garantía Garantía Limitada43041-01 01/31/2008 I d e ’ Installation Lire ET Conserver CES ConsignesEntretien Préventif Vérifier toutes les pièces. Si Avant l’installation Choisir votre option d’installation Nouvelle construction Fixation à une solive Souffleur Pendre PAR LE Câblage La page 62 pour fixer la grille Nouvelle construction suspendu entre des solivesFixer les glissières sur les vis B22 B23 Construction existante accessible du dessus C11 Ventilateur Existant SIN Ventilateur ExistantLa solive. Les vis ne sont pas fournies Serrer les vis du raccord Soufleur Pendre PAR LE Câblage Construction existante accessible uniquement du dessous Aller à l’ètape La page 62 pour fixer la grilleD15 D19 D20 Fixation de la grille Pendre PAR LE CâblagePoser des ampoules A15 de 60 w max. Non comprises Dépannage Garantie Garantie Limitée