Vent Height for Vertical Termination

TABLE 1

Roof Pitch

H (Min.) Ft.

Flat to 6/12

1.0

6/12 to 7/12

1.25

Over 7/12 to 8/12

1.5

Over 8/12 to 9/12

2.0

Over 9/12 to 10/12

2.5

Over 10/12 to 11/12

3.25

Over 11/12 to 12/12

4.0

Over 12/12 to 14/12

5.0

Over 14/12 to 16/12

6.0

Over 16/12 to 18/12

7.0

Over 18/12 to 20/12

7.5

Over 20/12 to 21/12

8.0

Vent Height

5.CHECK VENTING SYSTEM

Check the venting system to assure proper operation. This can be done with a match while the appliance is operating.

Hold a lighted match at the bottom edge of the draft hood opening. If the flames and smoke remain upright, ventilation is acceptable. If the flames and smoke are drawn into the draft hood, this means ventilation is good. If the flames and smoke are forced away from the draft hood, this may indicate a ventilation blockage or down draft resulting in gas spillage into the home. If this occurs, turn off the appliance and do not burn it until it has been inspected by a qualified service person. See Figure 8.

Figure 8

Testing Ventilation

6.INSTALLING AN OUTSIDE AIR KIT (STRONGLY RECOMMENDED)

An outside air kit should be purchased as a feature with this appliance. An outside air kit helps to decrease the amount of room air taken by utilizing outside air for combustion. Figure 9 illustrates two of many possible methods that can be used to supply outside air to the appliance.

A maximum of 40’ of air kit ducting is allowed. The air kit must terminate at least one foot below the venting termination and must terminate to the outside.

Note: The outside air kit can terminate at any level with the exception that it must terminate at least one foot be- low the vent termination cap. The outside air kit inlet thimble should be positioned at least four feet above the ground level in a manner that will not allow snow, leaves, etc. to block the inlet.

WARNING!

Exhaust products of gasoline engines are hazard- ous. The outside air must not be taken from a ga- rage space, attic spaces, basements or above the roofing where other heating appliances, fans or chimneys exhaust or utilize air.

12-02

9

34615 Rev G

Image 9
Contents Do not expose appliance to the elements such as rain, etc Novus Series Vent GAS ApplianceTable of Contents Design and Installation Considerations for B-VENTS Typical Vertical Installation Applicance SpecificationsGlass SPECIFICATIONS/CERTIFICATIONS S. and Canada CertificationAppliance Dimensions Installation ComponentLocation and Clearances Novus NomenclatureFraming Wear gloves and safety glasses for protectionAppliance Locations and Space Requirements ClearancesVenting Setting the ApplianceVent Height Attaching VentingFirestop SPACER/VENT Installation CHASE/TERMINATION InstallationInstalling the Firestop Spacer Testing Ventilation Installing AN Outside AIR KIT Strongly RecommendedCheck Venting System Vent Height for Vertical Termination Roof Pitch Min. FtOutside Air Locations Novus UtilitiesWall Switch WiringIntermittent Pilot Ignition Junction BOX Installation InstructionsAppliance Preparation FinishingAppliance Preparation Determining the Ignition TypeLog Set Placing the Rock WoolIntermittent Pilot Ignition Lighting Instructions Lighting InstructionsTo Turn OFF the GAS to the Appliance Intermittent Pilot IgnitionStanding Pilot Ignition To Turn OFF the GAS to ApplianceBefore Operating this Appliance have Qualified Technician Seasonal ChecklistStanding Pilot Ignition Operation Intermittent Pilot Ignition OperationOutside AIR KIT Operation START-UP IssuesMaintenance Instructions Cleaning the Burner and Control CompartmentChecking Flame Patterns Cleaning the Glass LOG REMOVAL/REPLACEMENTVenting System Inspection Optional Components Intermittent Pilot Conversion Kits Robertshaw Standing Pilot Conversion KitsTrim Kits Bay Door Trim KitQuick Tile Brass Surround Item # Description Qty Replacement PartsHomeowner’s Notes Index Year Limited Warranty Limited Lifetime WarrantyHow to Obtain Service Conditions, Exclusions, & Limitations of Liability

GNBC33, GNBC36, GNBC30 specifications

Hearth and Home Technologies (HHT) has established itself as a leading manufacturer of innovative and efficient hearth products, and its GNBC series of gas fireplaces – specifically the GNBC30, GNBC33, and GNBC36 – exemplifies this commitment to quality and performance. Each model in this series is designed to combine elegance with cutting-edge technology, ensuring a warm and inviting atmosphere in any home.

One of the main features of the GNBC series is its versatile design. These models are built to be multi-sided, offering a view of the flames from various angles, making them ideal centerpieces for both modern and traditional home interiors. The GNBC30, GNBC33, and GNBC36 showcase a minimalist aesthetic, available in multiple finishes and configurations, allowing homeowners to customize their spaces to reflect their personal style and preferences.

Efficiency is a crucial aspect of these gas fireplaces. The GNBC series utilizes advanced gas technology to provide clean and efficient heating, with a focus on maximizing warmth while minimizing energy consumption. These fireplaces are also equipped with smart electronic ignition systems, which enhance convenience and promote energy efficiency. By utilizing a thermostat, users can maintain their desired temperature effortlessly.

Safety is a top priority for HHT, and the GNBC series incorporates numerous safety features. The models come standard with a glass front and built-in safety screens, significantly reducing the risk of burns and accidents. Additionally, they feature a durable construction designed to last, ensuring that these fireplaces remain a safe and effective source of heat for years to come.

Another notable characteristic of the GNBC series is the ease of installation. Designed with the homeowner in mind, these fireplaces are relatively simple to integrate into a variety of architectural settings. The GNBC models can be vented through either natural ventilation or direct vent systems, allowing for greater flexibility based on the specific needs of the home.

In summary, Hearth and Home Technologies' GNBC30, GNBC33, and GNBC36 gas fireplaces offer a unique blend of style, technology, and safety. With their modern aesthetics, excellent efficiency ratings, and exceptional safety features, these fireplaces are an excellent choice for those seeking to enhance their living spaces while enjoying the benefits of a reliable heating source. Whether for new construction or renovation projects, the GNBC series stands out as a premier option for homeowners looking to elevate their hearth experience.