•The electrical connection should be made using a double pole isolating switch (cooker socket) with at least 3mm contact separation in all poles. The cable must have conductors of sufficiently high
•We recommend you use a new length of 6mm² twin core earthed cable to ensure your safety.
•The cable should be routed away from potentially hot areas.
Technical Data
Connection diagram is given as below:
|
|
|
|
|
|
|
|
|
|
| N - Neutral |
3 |
|
|
| N |
| 4 |
|
| PE - Earth | ||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| L - Live |
2 |
|
|
|
| 5 |
|
|
| |||
|
|
|
|
|
|
|
|
| |||
|
|
| L PE |
|
|
|
|
|
| ||
1 |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
| ||||
|
|
|
Overall height of appliance to top of hob
Maximum width of appliance Maximum depth of appliance Weight of the appliance
CERAMIC
895 mm
495mm
656mm
41,1kg
SOLID
898 mm
495mm
656mm
43,9kg
This appliance complies with: European Coun- cil Directive 73/23/EEC, EMC Directive 89/336/
EEC, CE Marking Directive 93/68/EEC, Energy Label Directive 2002/40/EC.
Technical Specifications for Top and Main Oven
Top Oven of 50x60 cooker
Top Heating Element
Bottom Heating Element
Grill Heating Element
Main Oven of 50x60 cooker
Ring Heating Element
Ceramic Hob
145 mm
Rating
500W
600W
1400 W
Rating
2000 W
Rating
1200 W
28