Zanussi ZGG 659 manual Commissioning, Procedure

Page 11

Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.

-Turn the gas tap to the MAX position and ignite.

-Set the gas tap to the MIN flame position then

turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.

Procedure:

 

 

Fig. 8

 

 

)

Re-ignite the burner and set to MIN.

 

By-pass screw

Remove the control knob, insert a thin

bladed screwdriver down the centre of the gas tap control shaft and turn the adjustment screw until the flame is steady and does not extinguish, when the knob is turned from MIN to MAX. Repeat this procedure for all burners.

11

Image 11
Contents GAS HOB Important Safety Information Contents Description of the Appliance InstallationLighting the burners Using the hob correctlyOperation Hob burners control knobsBurners Maintenance and CleaningHob Top Pan SupportsSomething Not Working? Instructions for the InstallerEngineers technical data Rectangular cut-out size for hob InstallationGas Connection Cut Out SizeBuilding over a kitchen unit with oven BuildingBuilding over a cupboard or drawer Building over a kitchen unit with doorPermanent Connection These safety measures not be observedFitting the hob to Worktop Electrical connectionCommissioning Procedure