Commissioning
When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.
-Turn the gas tap to the MAX position and ignite.
-Set the gas tap to the MIN flame position then
turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.
Procedure: |
|
| ||
Fig. 8 |
| |||
| ||||
) |
| |||
| ||||
Remove the control knob, insert a thin |
bladed screwdriver down the centre of the gas tap control shaft and turn the adjustment screw until the flame is steady and does not extinguish, when the knob is turned from MIN to MAX. Repeat this procedure for all burners.
11