operating it. This adjustment can be made by turning the levelling feet clockwise or
Connecting to the electricity supply
!WARNING!
This appliance must be earthed. Do not earth this appliance to gas supply piping. Connect to 230 - 240V AC supply only.
•Connection to the electricity supply must be carried out by a qualified electrician/competent person.
•The electrical connection should be made using a double pole isolating switch (cooker socket) with at least 3mm contact separation in all poles. The cable must have conductors of sufficiently high
•We recommend you use a new length of 6mm² twin core earthed cable to ensure your safety.
•The cable should be routed away from potentially hot areas.
Connection diagrams as given below:
N |
|
L | PE |
This appliance must be earthed.
For this connection, ‹Twin and Earth 6242Y›
type cable should be used.
N - Neutral
PE - Earth
L - Live
Technical Data
| CERAMIC | SOLID |
Overall height of appliance to top of | 895 mm | 898 mm |
hob |
|
|
|
|
|
Maximum width of appliance | 495 mm | 495 mm |
|
|
|
Maximum depth of appliance | 656 mm | 656 mm |
Weight of the appliance | 45,1kg | 43,9kg |
This appliance complies with: European Council Directive 73/23/EEC, EMC Directive 89/336/
EEC, CE Marking Directive 93/68/EEC, Energy Label Directive 2002/40/EC.
Technical Specifications for Top and Main Oven
Top Oven of 50x60 cooker | Rating |
Top Heating Element | 500 W |
Bottom Heating Element | 600 W |
|
|
Grill Heating Element | 1400 W |
|
|
Main Oven of 50x60 cooker | Rating |
Ring Heating Element
2000 W
20