Toastmaster TMRC36, TMRC48 GAS Piping, GAS Pressure Regulator, Manual Shut OFF Valve, Propane GAS

Page 5

2M-Z12963: Gas Radiant & Lava Rock Charbroilers TMRC & TMLC

CAUTION

GAS PIPING

Gas piping shall be of such size and so installed as to provide a supply of gas sufficient to meet the full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked to determine if it has adequate capacity. Joint compound shall be used sparingly and only on the male threads of the pipe joints. Such compounds shall be resistant to the action of L.P. gases.

WARNING: Any loose foreign material, debris, or metal particles allowed to enter the gas lines on this appliance will damage the valve and affect its operation. When installing this appliance,

all pipe and fittings must be free from all internal loose dirt.

GAS PRESSURE REGULATOR

A convertible pressure regulator is provided with each charbroiler. It should be connected to the inlet pipe at the rear of the unit. The gas supply is then connected to it. It is shipped set for 6" water column manifold pressure for use with natural gas. Allow 6" clearance from back of unit to wall for servicing and installation.

MANUAL SHUT OFF VALVE

A manual shut off valve should be installed upstream from the manifold and within six feet of the charbroiler.

CONNECTING GAS SUPPLY LINE

The gas inlet of the charbroiler is sealed at the factory to prevent entry of dirt. Do not remove this seal until the actual connection is made to the gas supply line.

PROPANE GAS

This charbroiler is equipped with fixed orifice hoods and is shipped from the factory for use with natural gas. To convert to propane gas, install the burner orifice hoods, included with the unit, as follows:

1.Remove grill, radiants and burners.

2.Remove the burner orifice hoods and install the orifice hoods supplied.

3.Replace the burners, radiants, and grill.

4.Set manifold pressure to (10) inch water column. A 1/8" pipe plug on the burner manifold can be removed for attaching a pressure gauge. Remove the slotted, or hex-threaded plug from the pressure regulator. Invert the plug and re-install. The letters "LP" should now be visible on the plug. The regulator is now set for 10" (25.4 cm) water column. Attach the conversion label, supplied with the unit, close to the nameplate.

CHECKING FOR GAS LEAKS

Check entire piping system for leaks. Soap and water solution or other material acceptable for the purpose shall be used in locating gas leakage.

Matches, candle flame or other sources of ignition shall not be used for this purpose.



Image 5
Contents GAS Charbroiler Service Help Desk Safety SymbolsModel TMLC24, TMLC36, TMLC48, TMRC24, TMRC36, TMRC48 Specifications Gas CharbroilerExhaust Canopy For Your SafetyAIR Supply Leveling UnitGAS Piping Connecting GAS Supply LineGAS Pressure Regulator Manual Shut OFF ValvePilot Lighting Instructions Burner Ignition and AdjustmentShutting Down Instructions Placing Lava Rock on Grates for Tmlc SeriesWater PAN / Drip Tray CleaningLighting Seasoning the Cooking Grates14 13 Parts List Pilot Bracket Exceptions Length of Warranty2M-Z12963 Gas Radiant & Lava Rock Charbroilers Tmrc & Tmlc 2M-Z12963 Gas Radiant & Lava Rock Charbroilers Tmrc & Tmlc 2M-Z12963 Gas Radiant & Lava Rock Charbroilers Tmrc & Tmlc Nettoyage Fonctionnement DE InstructionsAjustement ET Brûleur DU Ignition ’ALLUMAGE Veilleuses LES Concernant Instructions ’ÉTANCHÉITÉ DE VérificationSécurité DE Esure ’INSTALLATION Générales DonnéesRéparations ET Entretien Autorisé service de AgentGAZ a Barbecue