Hazardous voltages exist at the outputs and the load connections. To
protect personnel against accidental contact with hazardousvoltages,
ensure that the load
and its connections have no accessible livepart s.
Ensure that the load wiring insulation rating is greater than or equal to
the maximum output voltage of the power supply.
Shield
M10x25screw (2 places)
HexNut (2 places)
Flatwasher (2 places)
Springwasher (2 places)
Wire terminal lug (2 places)
Flatwasher
(2places)
Screwstightening torque:290-310 Lb-inch.
Fig. 3
-
6: Load wires connection, 8V to 100V models
Fig. 3
-
7: Bus
-
bars shield mounting
150V to 600V Models
The 150V to 600V models have a four terminal wire clamp output connector. The two left terminals
are the positive outputs and the two right terminals are the negative outputs. Max. 30A per terminal.
The connector r
e
quirements are as follows: