8.1 INTRODUCTION

Isolated Analog Programming
is an internal Option Card for analog programming of the Genesys
TM
power supply series. The option is factory installed and cannot be obtained with a GPIB (IEEE
-
488)
Interface. Output Voltage and Output Current can be programmed and readback through optica
lly is
o-
lated si
g
nals which are isolated from all other ground references in the power supply.
There are two types of Isolated Analog programming cards:
1.
0
-
5V/0
-
10V option (PN: IS510): Using 0
-
5V or 0
-
10V signals for programming and readback.
2.
4
-
20mA option (
PN: IS420): Using current signals for programming and readback.

8.2 SPECIFICATIONS

8.2.1
0
-
5V/0
-
10V OPTION (PN: IS510)
Output Voltage programming accuracy
%
+/
-
1
Output Current programming accuracy
%
+/
-
1
Output Voltage programming temper
ature coefficient
PPM/
°
C
+/
-
100
Output Current programming temperature coefficient
PPM/
°
C
+/
-
100
Input impedance
Ohm
1M
Absolute maximum voltage
Vdc
0
-
15
Progra
m
ming
Inputs
Max. voltage between program inputs and supply outputs
Vdc
600
Output Volt
age monitoring accuracy
%
+/
-
1.5
Output Current monitoring accuracy
%
+/
-
1.5
Output Impedance (see Note)
Ohm
100
Monitoring
Outputs
Max. voltage between monitoring outputs and supplyou
t
puts
Vdc
600
NOTE:
Use 100Kohm minimum input impedance for the monitoring circuit
s to minimize the readback error.
8.2.2
4
-
20mA option (PN: IS420)
Output Voltage programming accuracy
%
+/
-
1
Output Current programming accuracy
%
+/
-
1
Output Voltage programming temperature coefficient
PPM/
°
C
+/
-
200
Output Current progr
amming temperature coefficient
PPM/
°
C
+/
-
200
Input impedance
Ohm
50
Absolute maximum input current
Vdc
0
-
30
Progra
m
ming
Inputs
Max. voltage between program inputs and supply outputs
Vdc
600
Output Voltage monitoring accuracy
%
+/
-
1.5
Output Curren
t monitoring accuracy
%
+/
-
1.5
Maximum load impedance
Ohm
500
Monitoring
Outputs
Max. voltage between monitoring outputs and supplyou
t
puts
Vdc
600