83
-
5
15
-
0
00
Rev.
B

6

1.1 USER MANUALCONTENT

This User’s
Manual contains the operating instructions, installation instructions and specifications of
the Genesys
TM
50
00W power supply series. The instructions refer to the standard power supplies,
including the built
-
in RS232/RS485 serial communication. For inform
ation related to operation with the
optional IEEE programming, refer to User Manual for Power SupplyI EEEProgramm ing Inte
r
face.

1.2 INTRODUCTION

1.2.1
General Description
Genesys
TM
power supplies are wide output range, high performance switching power supplies
. The
Genesys
TM
series is power factor corrected and operates from AC voltage range of 190
-
240VAC
three phase for 200V models and 380
-
41
5
VAC three phase for 400VAC models. Output Voltage and
Current are continuously displayed and LED indicators show the co
mplete operating status of the
power supply. The Front panel controls allow the user to set the output parameters, the protections
levels (Over
-
Voltage protection, Under
-
Voltage limit and Foldback) and preview the se
t
tings. The rear
panel includes the nece
ssary connectors to control and monitor the power supply operation by remote
analog signals or by the built
-
in serial communication (RS232/RS485).GPIB programming
, LXI cert
i-
fied LAN and
Isolated
-
Analog programming/monitoring
are optional.
1.2.2
Models covered by
this Manual
Models with rated output from 0
-
8VDC/0
-
600A to 0
-
600VDC/0
-
8.5A.
Model
Voltage range
(V)
Current
range (A)
GEN 8
6
00
0
-
8
0
-
6
00
GEN 10
-
50
0
0
-
10
0
-
50
0
GEN 1
6
-
31
0
0
-
1
6
0
-
31
0
GEN 20
-
2
5
0
0
-
20
0
-
2
5
0
GEN 30
-
1
7
0
0
-
30
0
-
1
7
0
GEN 40
-
12
5
0
-
40
0
-
12
5
GEN 60
-
8
5
0
-
60
0
-
8
5
GEN 80
-
65
0
-
80
0
-
65
GEN 100
-
50
0
-
100
0
-
50
GEN 150
-
34
0
-
150
0
-
34
GEN 300
-
17
0
-
300
0
-
1
7
GEN 600
-
8.5
0
-
600
0
-
8
.5
1.2.3
Features and options
Constant Voltage / Constan
t Current with automatic crossover.
Active power factor correction.
Embedded Microprocessor Controller.
Built
-
in RS232/485 Interface.
Voltage & Current high resolution adjustment by digital encoders.
High accuracy programming/readback
-
16 bit.
Software Cali
bration (no internal trimmers / potentiometers).
Last Setting Memory.
Independent Remote ON/OFF (opto
-
isolated) and remote Enable/Disable.
Parallel operation (Master/Slave) withActive current sharing.
Remote sensing to compensate for voltage drop of power
leads.
External Analog Programming and Monitoring standard(0
-
5V or 0
-
10V, user selectable).