ting power supplies in a “Daisy

-

chain” (refer to Section 5.16). The SO control can

also be used to reset the OVP and Fold Protection (refer to Section 5.3 and 5.5 for details).

When the unit is shut

-

off by a J1 signal, the VOLTAGE display will show “SO” to

indicate the unit

state. J1 contact 15 is the SO signal input and contacts 2 and 3, IF_COM, are the signal return (co

n-

nected internally). Co

n

tacts 2, 3 and 15 are optically isolated from the power supply output.

The SO control logic can be selected by the

rear panel SW1 Setup switch. Refer to Table 5

-

2 for

SW1 setting and SO Control Logic.

SW1
-
5 setting
SO signal level
J1
-
2(3), 15
Power supply
output
Display
Down (default)
2
-
15V or Open
0
-
0.6V or Short
On
Off
Voltage/Current
“SO”
Up
2
-
15V or Open
0
-
0.6V
or Short
Off
On
“SO”
Voltage/Current
Table 5
-
2: SO logic selection
5.8
ENABLE/DISABLE CONTROL VIAREAR PANEL J1 CONNECTOR
Contacts 1 and 14 of J1 (Fig.4
-
2, item 5) serve as Output Enable/Disable terminals by switch or relay.This f un
c-
tion is Enabled o
r Disabled bythe SW 1 Setup switch position 9. Refer to Table 5
-
3 for Enable/Disable function
and SW1 setting.
SW1
-
9 setting
Enable/DisableI
n
puts
Power supply ou
t
put
Display
ALARM LED
Down (Default)
Open or Short
On
Vol
t
age/Current
Off
Open
Off
“ENA”
Blinking
Up
Short
On
Voltage/Current
Off
Table 5
-
3: Enable/Disablef unction and SW1 setting
5.9 CV/CC SIGNAL
CV/CC signal indicates the operatingm ode of the power supply,Constant Voltage or Constant Current

.

The
CV/CC signal is an open collector out
put with a 30Vparallel zener, at J1
-
13, referenced to the COM potential at
J1
-
12 (connected internallyto the negative sense potential). W hen the powersupply operates in Constant Vol
t-
age mode, CV/CC output is open. When the power supply operates in Const
ant Current mode, the CV/CC signal
ou
t
put is low (0
-
0.6), with maximum 10mA sink current.
5.10 PS_OK SIGNAL
The PS_OK signal indicates the fault condition of the power supply.PS_OK is a TTL s ignaloutput at J1
-
16, re
f-
erenced to IF_COM at J1
-
2, 3 (Isolat
ed Interface Common). When a fault condition occurs, the PS_OK level is
low, witha m aximum sink current of 1mA; when no fault condition occurs, the PS_OK level is high with a max
i-
mum source current of 2mA. The following faults will set the PS_OK to a Faul
t state:

CAUTION

To prevent possible damage to the unit, do not connect anyof the
Enable/Disableinputs to the positive or negative output potential.

NOTE

Safe Start mode
-
If the Ena
ble/Disable fault condition clears when units in safe start mode
recoveryis bypressing OUT button or by sending an ‘OUT 1’ serial command.
Auto R
e
start
mode
-
The output will return back ON automatically when the Enable/Disable
fault cond
i
tions clears.

CAUTION

Do not connect the CV/CC signal to a voltages ource higher than30VDC. Always
connect the CV/CC signal to vol
tage source with a series resi
s
tor to limit the sink
current to less than 10mA.