16
Unscrew the base of the strain relief from the helix
-
shaped body. Insert the base through the
outside opening in the AC i
n
put cover and screw the locknut securely (11
-
14 Lb
-
inch.) (1.3
-
1.6Nm)
in
to
the base, from the i
n
side.
Slide the helix
-
shaped body onto the AC cable. Insert the stripped wires through the strain r
e-
lief base until the outer cable jacket is flush with the edge of the base. Tighten (16
-
18 Lb
-
inch.)
(18
-
20Nm) the body to the base
while holding the cable in place. Now the cable is securely
fastened inside the strain relief. R
e
fer to Fig. 3
-
2.
4.
Connec
t
the AC wires to the terminals of the input plug supplied with the unit. To connect the wires,
loosen the terminal screw, insert th
e stripped wire into the terminal and tighten the screw securely (
10.7
-
13.4
Lb
-
inch). (
1.21
1.5
Nm) Refer to Fig. 3
-
3 for details. Payattention to connect the wires according to
the polaritym arking on the plug.
Fig.3
-
3: AC Input plug (3
-
Phase shown)
5.
C
onnect the AC input plug to the AC input connector at the power supply rear panel. Fasten the plug to
the connector using the two screws at each side of the plug.
(Tightening torque: 10.7
-
13.4Lb inch)
Route the wires inside the cover to prevent pinching. F
asten the cover to the unit using the M3x8 Flat
Head screws are provided. Refer to Fig.3
-
4 for details. Tighten screws securely (4.8
-
4.9LB
-
inch, 0.54
-
-
0.55 Nm)
Fig.3-2: Stripped Wires installed in Strain Relief
Screw-on
Locknut