REAR VIEW
INPUT A / INPUT B |
The inputs INPUT A & INPUT B are electronically
balanced offering an input sensitivity of +6dBu (1.55V)
for direct connection of mixing consoles, etc. Connection can be established via the
connectors or the supplied
IEC 268 standard. In case floating inputs are needed, retrofitting optionally available input transformers is possible. One
PARALLEL CONNECTION
Connection can be established via the
DSP OUT
The DSP output signal – i.e. the
The DSP OUT can be utilized for feeding the digitally processed audio signal from the
CONTROL PORT
The CONTROL PORT offers two freely programmable control inputs and
control outputs as well as the reference connections for ground potential and +5V. Using the PC Windows software IRIS, the control inputs can be
configured and serve for instance for
switching or parameter control.
The two control contacts IN1 / IN2 are internally set to +5V (open) via
The outputs serve for signalling internal operational states. They can be used for the direct triggering of LEDs, indication lights or relays. The +5V reference connector provides power supply for externally connected appliances with amperage of maximally 100mA. The control outputs allow signal indication of operational states (critical temperature, exceeding or decline of defined limit values, faults, etc.) at central operator desks or to other systems (fire alarm system, general alert system) even without PC. For further detail about configuring the control ports, please refer to the documentation accompanying the IRIS software.