Electro-Voice P3000RL owner manual Front View

Page 6

FRONT VIEW

Use the POWER switch located in the centre of the front panel to switch the appliance’s power on. The soft-start function prevents current inrush peaks on the mains, which in addition prevents the mains line protection switch from activating during power-on operation of the power amplifier. The loudspeaker outputs are activated via relay switching with a delay of approximately 2 seconds effectively attenuating eventual power-on noise. The PROTECT LED lights during the delay time and the fans run at maximum speed. This is normal to confirm the immaculate operation of the protection circuitry. Upon power-on, all power amps with RCM-24 Module installed regain the state of operation prior to the last power-off.

For example: if a power amplifier had been switched off using the POWER-switch while being in Stand- by mode, upon power-on it restarts in this exact mode.

This indicator lights when the power amplifier has been switched on. Causes for the POWER-indicator not lighting are: the appliance is not connected to the mains network, a defective primary fuse, or the power amplifier is set to stand-by operation (STAND-BY LED lights).

This indicator light when the power amplifier is in stand-by mode, which can be activated from the RCM-24 or via Easy Remote. In stand-by operation only the internal auxiliary power supply unit is activated. The main power supply unit is separated from the mains.

The PROTECT LED lights indicating that one of the internal protection circuits against thermal overload, short-circuit, Back-EMF, HF-occurrence at the output, etc., has been activated. In that case, the output relays separate the power amps from the load connected to prevent the connected loudspeaker systems and the power amplifiers as well from being damaged. Whatever caused the fault – e.g. a short- circuited speaker cable – needs to be remedied. In case of thermal overload you have to wait until the power amplifier automatically regains normal operation.

The OUT LED lights as soon as an audio signal of approximately 30dB below full modulation is present. The LED is dimmed when speaker cables are short-circuited or a protection circuit has been activated.

The 0dB LED lights when the power amplifier is driven at its maximum. Higher input voltage does not result in higher peak output voltage.

This indicator lights as soon as the integrated dynamic limiter is activated and the power amplifier is driven at the clipping limit or generally at its maximum capacity. Short-term blinking is not a problem, since the internal limiter trims input levels of up to +21dBu down to a S/N-ratio of approximately 1%. If, on the other hand, this LED lights constantly, reducing the volume is recommended to prevent the loudspeaker systems connected from being damaged by probable overload.

6

Image 6
Contents OWNER‘S Manual Bedienungsanleitung Contents InhaltImportant Service Instructions Description Unpacking & Warranty Installation Notes Front View DSP OUT Rear ViewParallel Connection Control PortRS-232 Interface AddressRemote can BUS Power Amplifier Outputs GROUND-LIFT SwitchEasy Remote Bridged Mode Remote Control Network CablingLF-CONNECTION Cords Network Examples Network Examples Cable Specifications CAN-BUSMains Operation & Resulting Temperature Resulting Temperature Inside the Power AmplifierMains Operation Page Bedienungsanleitung Inhalt Wichtige Sicherheitshinweise Beschreibung Installationshinweise Auspacken & GarantieFrontseite Input a / Input B ParallelRückseite Endstufenausgänge GROUND-LIFT SchalterBridged Mode Remote Control Netzwerk VerkabelungNF-VERBINDUNGSKABEL NETZWERK-BEISPIELE NETZWERK-BEISPIELE Leitungsspezifikationen Netzbetrieb & Wärmeentwicklung NetzbetriebWärmeentwicklung in DER Endstufe Specifications / Technische Daten DIM30Power Requirements Block Diagram Amplifier Block Diagram RCM-24 Channel BDimensions / Abmessungen 440,5 132,5Page Page Page USA